Hayward W3AQ-TROL-RJ AquaTrol-Above-Ground-Chlorine-Generator-Owners-Manual-09 - Page 8

Controls - manual

Page 8 highlights

Controls Timer The pool filter pump should run long enough to circulate the entire volume of pool water each day. This will vary depending on pump size, pool plumbing and pool size. Consult a local pool store to help determine the appropriate run time for your pool. Set the AquaTrol's timer by rotating the clock hands in a clockwise direction. The arrow (positioned approximately 2 o'clock on dial) points to the current time. The internal "hands" show time at a glance. On the outside of the timer, there are a series of small slide trippers. Each tripper controls a 15 minute interval. Set the trippers for the desired run time. OFF - Push trippers IN (toward center) ON - Pull trippers OUT (away from center) Manual Control There is a switch on the timer (located at approximately the 4 o'clock position) that allows the pump to be manually turned on or off. "1" (up) - pump ON " " (center) - timer controls pump "0" (down) - pump OFF Main Switch AUTO: For normal operation, the Main Switch should be left in the AUTO position. In this position the AquaTrol® will produce chlorine according to the "Desired Level %" adjustment setting for the entire filtering/pumping cycle. SUPER CHLORINATE: When you have an abnormally high bather load, a large amount of rain, a cloudy water condition, or any other condition which needs a large amount of purification to be introduced, put the Main Switch in the SUPER CHLORINATE position. This electronically "super chlorinates" (shocks) the water for 24 hours (filter pump must be on during this time) or until the power has been turned off, whichever comes first. At the end of the super chlorinate time, be sure to put the switch back into the AUTO position. OFF: The OFF position prevents the AquaTrol from energizing the electrolytic cell. In this position there is no chlorine generation. NOTE: To service any of the pool equipment or the AquaTrol, turn the power off at the circuit breaker. "Desired Level %" adjustment knob This setting is used to control the amount of chlorine the AquaTrol generates. Raise this setting to increase chlorine level and lower it to decrease chlorine level. Indicator LED's POWER When illuminated, the AquaTrol has input power. GENERATING This LED is on steady during normal operation. When flashing, the pool water is too hot or cold to operate. SUPER CHLORINATE Illuminates during Super Chlorination. See description above. 6 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6
Controls
Timer
The pool filter pump should run long enough to circulate the entire volume of pool water each day.
This will vary depending on pump size, pool plumbing and pool size.
Consult a local pool store to
help determine the appropriate run time for your pool.
Set the AquaTrol’s timer by rotating the clock hands in a clockwise direction.
The arrow (positioned
approximately 2 o’clock on dial) points to the current time.
The internal “hands” show time at a
glance.
On the outside of the timer, there are a series of small slide trippers.
Each tripper controls
a 15 minute interval.
Set the trippers for the desired run time.
OFF
- Push trippers IN (toward center)
ON
- Pull trippers OUT (away from center)
Manual Control
There is a switch on the timer (located at approximately the 4 o’clock position) that allows the pump
to be manually turned on or off.
“1”
(up)
- pump ON
(center) - timer controls pump
“0”
(down) - pump OFF
Main Switch
AUTO:
For normal operation, the Main Switch should be left in the AUTO position.
In this position the
AquaTrol
®
will produce chlorine according to the “Desired Level %” adjustment setting for the entire
filtering/pumping cycle.
SUPER CHLORINATE:
When you have an abnormally high bather load, a large amount of rain, a
cloudy water condition, or any other condition which needs a large amount of purification to be
introduced, put the Main Switch in the SUPER CHLORINATE position.
This electronically “super chlo-
rinates” (shocks) the water for 24 hours (filter pump must be on during this time) or until the power
has been turned off, whichever comes first.
At the end of the super chlorinate time, be sure to put
the switch back into the AUTO position.
OFF:
The OFF position prevents the AquaTrol from energizing the electrolytic cell.
In this position
there is no chlorine generation.
NOTE:
To service any of the pool equipment or the AquaTrol, turn
the power off at the circuit breaker.
“Desired Level %” adjustment knob
This setting is used to control the amount of chlorine the AquaTrol generates.
Raise this setting to
increase chlorine level and lower it to decrease chlorine level.
Indicator LED’s
POWER
When illuminated, the AquaTrol has input power.
GENERATING
This LED is on steady during normal operation.
When flashing, the pool water is too
hot or cold to operate.
SUPER CHLORINATE
Illuminates during Super Chlorination.
See description above.