HealthRider H70t Treadmill English Manual - Page 12

If You Do Not Connect The Con, Become Damaged When You Turn

Page 12 highlights

8. If there are four screws (B) preattached inside the Right and Left Handrails (84, 85), remove and discard the screws. IMPORTANT: To avoid damaging the Pulse Crossbar (31), do not use power tools and do not overtighten the #10 x 1 1/4" Screws (9). 89 5 85 Orient the Pulse Crossbar (31) as shown. Attach B the Pulse Crossbar to the Handrails (84, 85) with four #10 x 1 1/4" Screws (9) and four #10 Star Washers (5); start all four Screws, and then tighten them. 31 9 5 B 84 9. With the help of a second person, hold the console assembly near the Right Handrail (84) and 9 the Left Handrail (not shown). Next, connect the ground wire from the console assembly to the Console Ground Wire (58) on the Pulse Crossbar (31). Console Assembly  See the inset drawing. Connect the Upright Wire (81) to the console wire. The connectors should slide together easily and snap into place. If they do not, turn one connector and try Console again. IF YOU DO NOT CONNECT THE CON- Wire NECTORS PROPERLY, THE CONSOLE MAY 81 BECOME DAMAGED WHEN YOU TURN ON THE POWER. Then, remove the wire tie from 84 the Upright Wire. Wire 31 Tie Ground Wire 58 Console Wire 81 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

12
31
85
8
8.
If there are four screws (B) preattached inside
the Right and Left Handrails (84, 85), remove
and discard the screws.
IMPORTANT: To avoid damaging the Pulse
Crossbar (31), do not use power tools and do
not overtighten the #10 x 1 1/4" Screws (9).
Orient the Pulse Crossbar (31) as shown. Attach
the Pulse Crossbar to the Handrails (84, 85) with
four #10 x 1 1/4" Screws (9) and four #10 Star
Washers (5);
start all four Screws, and then
tighten them.
9.
With the help of a second person, hold the con-
sole assembly near the Right Handrail (84) and
the Left Handrail (not shown).
Next, connect the ground wire from the console
assembly to the Console Ground Wire (58) on
the Pulse Crossbar (31).
See the inset drawing.
Connect the Upright
Wire (81) to the console wire.
The connectors
should slide together easily and snap into
place.
If they do not, turn one connector and try
again.
IF YOU DO NOT CONNECT THE CON
-
NECTORS PROPERLY, THE CONSOLE MAY
BECOME DAMAGED WHEN YOU TURN ON
THE POWER.
Then, remove the wire tie from
the Upright Wire.
9
Console
Assembly
81
Wire
Tie
Console
Wire
Console
Wire
81
84
Ground
Wire
31
9
9
5
5
84
B
B
58