HealthRider R 60 English Manual - Page 27

Plug The Power Cord.

Page 27 highlights

PROBLEM 4. The walking belt is off-center or slips when walked on SOLUTION a. If the walking belt is off-center, first re- a move the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered. b. If the walking belt slips when walked on, b first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller bolts clockwise 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key, and walk on the tread- mill for a few minutes. Repeat until the walking belt is properly tightened. 5. The displays of the console do not function properly a. Remove the key from the console and UN- a PLUG THE POWER CORD. Next, remove 1/8" the screws from the hood and carefully re- move the hood. Locate the Reed Switch 44 11 (17) and the Magnet (12) on the left side of 17 12 the Pulley (11). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Top View Magnet and the Reed Switch is about 1/8". If necessary, loosen the indicated Screw (44) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood and run the treadmill for a few minutes to check for a correct speed reading. 6. The heart rate monitor a. If the heart rate monitor does not function properly, does not function refer to CHEST PULSE SENSOR TROUBLESHOOT- b properly ING on page 8. b. If the heart rate monitor still does not function properly, the battery should be changed. To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover and turn the cover counterclockwise to the "open" position. Remove the cover. Next, remove the old battery from the sensor unit. Insert a new CR 2032 battery, making sure that the writing is on top. In addition, make sure that the rubber gasket is in place in the sensor unit. Replace the battery cover and turn it to the closed position. CR2032 Battery Rubber Gasket 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

27
PROBLEM
SOLUTION
a. If the walking belt is off-center, first re-
move the key and
UNPLUG THE POWER
CORD
.
If the walking belt has shifted to
the left,
use the allen wrench to turn the
left rear roller bolt clockwise 1/2 of a turn;
if
the walking belt has shifted to the right,
turn the bolt counterclockwise 1/2 of a turn.
Be careful not to overtighten the walking
belt. Plug in the power cord, insert the key
and run the treadmill for a few minutes.
Repeat until the walking belt is centered.
b. If the walking belt slips when walked on,
first remove the key and
UNPLUG THE
POWER CORD
. Using the allen wrench,
turn both rear roller bolts clockwise 1/4 of a
turn. When the walking belt is correctly
tightened, you should be able to lift each
side of the walking belt 3 to 4 inches off the
walking platform. Be careful to keep the
walking belt centered. Plug in the power
cord, insert the key, and walk on the tread-
mill for a few minutes. Repeat until the walking belt is properly tightened.
a. Remove the key from the console and
UN-
PLUG THE POWER CORD.
Next, remove
the screws from the hood and carefully re-
move the hood. Locate the Reed Switch
(17) and the Magnet (12) on the left side of
the Pulley (11). Turn the Pulley until the
Magnet is aligned with the Reed Switch.
Make sure that the gap between the
Magnet and the Reed Switch is about
1/8”.
If necessary, loosen the indicated
Screw (44) and move the Reed Switch slightly. Retighten the Screw. Re-attach the
hood and run the treadmill for a few minutes to check for a correct speed reading.
a. If the heart rate monitor does not function properly,
refer to CHEST PULSE SENSOR TROUBLESHOOT-
ING on page 8.
b. If the heart rate monitor still does not function properly,
the battery should be changed. To replace the battery,
locate the battery cover on the back of the sensor unit.
Insert a coin into the slot in the cover and turn the
cover counterclockwise to the “open” position.
Remove the cover.
Next, remove the old battery from the sensor unit.
Insert a new
CR 2032 battery
, making sure that the
writing is on top. In addition, make sure that the rubber
gasket is in place in the sensor unit. Replace the bat-
tery cover and turn it to the closed position.
a
b
4. The walking belt is
off-center or slips
when walked on
5. The displays of the
console do not func-
tion properly
6. The heart rate monitor
does not function
properly
12
17
44
Top
View
1/8”
11
a
CR2032
Battery
Rubber
Gasket
b