HP 8/40 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 566
SYSM-1004, Indicates this chassis type is not compatible with the control processor CP blade.
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 566 highlights
83 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Verify that the world wide name (WWN) card is present and operational and that the affected Action control processor (CP) is properly seated in its slot. Severity ERROR SYSM-1005 Message , [SYSM-1005], , FFDC, CRITICAL, , CP blade in slot failed to retrieve current chassis type. Probable Cause Indicates there was a failure to read the chassis type from the system. Recommended Verify the control processor (CP) blade is operational and is properly seated in its slot. Action Severity CRITICAL SYSM-1006 Message , [SYSM-1006], , FFDC, CRITICAL, , CP blade in slot is incompatible with the chassis type. Probable Cause Indicates this chassis type is not compatible with the control processor (CP) blade. Recommended Use the CP blade on a compatible chassis. Action Severity CRITICAL SYSM-1007 Message , [SYSM-1007], ,, WARNING, , PERMITTING USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT . DATA ERRORS MAY RESULT. Probable Cause Over-riding the incompatible control processor (CP)/chassis check. For engineering use only. Recommended Delete the /var/chassis_backplane_override file and reboot the CP. Action Severity WARNING 508 Fabric OS Message Reference 53-1001157-01