RS-232 connection
View all HP 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
7 RS-232 connection Recommended HP cable: HP 40220 to HP2334/5 for printer access (depends upon termtype used HP3000 and upon type of printer). 25-pin male connector to DTC 1 - PGND 2 - RD 3 - TD 4 - DCD 5 - GPO 6 - DTR 7 - SGND 8 - RTS 20 - DSR 22 - CTS INPUT OUTPUT INPUT OUTPUT OUTPUT OUTPUT INPUT INPUT Note To be used with US modem behavior only. 25-pin female connector to HP 2334/5 1 - PGND 3 - TD 2 - RD 8 - DCD 6 - DRS 20 - DTR 7 - SGND 4 - RTS 5 - CTS OUTPUT INPUT OUTPUT OUTPUT INPUT INPUT OUTPUT 61
61
RS-232 connection
7
Note
To be used with US modem behavior only.
Recommended HP cable:
HP 40220 to HP2334/5 for printer access
(depends upon termtype used HP3000 and upon
type of printer).
25-pin male connector to DTC
1 - PGND
-
2 - RD
INPUT
3 - TD
OUTPUT
4 - DCD
INPUT
5 - GPO
OUTPUT
6 - DTR
OUTPUT
7 - SGND
-
8 - RTS
OUTPUT
20 - DSR
INPUT
22 - CTS
INPUT
25-pin female connector to
HP 2334/5
1 - PGND
-
3 - TD
OUTPUT
2 - RD
INPUT
8 - DCD
OUTPUT
6 - DRS
OUTPUT
20 - DTR
INPUT
7 - SGND
-
4 - RTS
INPUT
5 - CTS
OUTPUT