HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 11

Important notes, New OUI support on B-series platforms

Page 11 highlights

Feature DCFM Professional DCFM Professional Plus DC Director Switch MP Yes Yes Extension Blade Real time stats1 Yes Yes Historical stats2 No Yes DBMS (ODBC & JDBC) No Yes Partner software No Yes nl integration Role Based Access No Yes nl Control (RBAC) FICON No No DC SAN Backbone No No nl Director 1Real-time stats for GE ports. FC ports, E-E Monitors, and TopTalkers 2Historical stats for FC ports and E-E Monitors DCFM Enterprise Yes Yes Yes Yes Yes Yes Yes Yes Important notes This section provides information that you should consider before using DCFM V10.3.x. See the Data Center Fabric Manager Enterprise, Professional Plus, or Professional User Manual for details on the following notes. These documents can be downloaded from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html Under Support, click HP Support & Documents, and then click Manuals. Under User guide, select the appropriate edition. NOTE: Install DCFM on a dedicated machine that is not running any other server applications, such as another database server. New OUI support on B-series platforms The OUI value is part of a Fibre Channel WWN that uniquely identifies the manufacturer of Fibre Channel products. The OUI values assigned to Brocade are used by Fabric OS to validate certain fabric interoperability support, and by DCFM to provide for manageability features. Brocade is near to exhausting the currently assigned OUI/WWN values. Therefore, they will soon be using a new OUI value for WWN assignment. WWNs with the current OUI value are expected to be consumed by mid-2010. Brocade factory shipments of switches after this time will have WWNs that include the new OUI. The new OUI value for Brocade is 00:05:33. For example, a WWN of 10:00:00:05:33:41:5c:c1 uses the new OUI. DCFM 10.3.4 has been enhanced to recognize the new Brocade OUI value to guarantee proper functionality. B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

DCFM Enterprise
DCFM Professional Plus
DCFM Professional
Feature
Yes
Yes
Yes
DC Director Switch MP
Extension Blade
Yes
Yes
Yes
Real time stats
1
Yes
Yes
No
Historical stats
2
Yes
Yes
No
DBMS (ODBC & JDBC)
Yes
Yes
No
Partner software
nl
integration
Yes
Yes
No
Role Based Access
nl
Control (RBAC)
Yes
No
No
FICON
Yes
No
No
DC SAN Backbone
nl
Director
1
Real-time stats for GE ports. FC ports, E-E Monitors, and TopTalkers
2
Historical stats for FC ports and E-E Monitors
Important notes
This section provides information that you should consider before using DCFM V10.3.
x
. See the Data
Center Fabric Manager Enterprise, Professional Plus, or Professional User Manual for details on the
following notes. These documents can be downloaded from the following HP website:
h
t
tp://h18
006
.w
w
w1.hp
.co
m/pr
odu
c
ts/s
t
o
r
age
w
o
r
ks/dc_f
a
br
i
cmgr/inde
x
.h
tml
Under Support, click
HP Support & Documents
, and then click
Manuals
. Under User guide, select the
appropriate edition.
NOTE:
Install DCFM on a dedicated machine that is not running any other server applications, such as another
database server.
New OUI support on B-series platforms
The OUI value is part of a Fibre Channel WWN that uniquely identifies the manufacturer of Fibre
Channel products. The OUI values assigned to Brocade are used by Fabric OS to validate certain
fabric interoperability support, and by DCFM to provide for manageability features.
Brocade is near to exhausting the currently assigned OUI/WWN values. Therefore, they will soon
be using a new OUI value for WWN assignment. WWNs with the current OUI value are expected
to be consumed by mid-2010. Brocade factory shipments of switches after this time will have WWNs
that include the new OUI.
The new OUI value for Brocade is
00:05:33
. For example, a WWN of
10:00:
00:05:33
:41:5c:c1
uses the new OUI.
DCFM 10.3.4 has been enhanced to recognize the new Brocade OUI value to guarantee proper
functionality.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional