HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 27

Unable to launch Server Management Console SMC when the Win, Server Port Mapping, Product List, Search

Page 27 highlights

Closed defect summary Solution Occasionally, a large database fails to be imported in interopmode 0 and interopmode 2, resulting in a violation error. Fixed in DCFM 10.3.0 Unable to activate, clear all, or delete a large zone database (1MB) when in interopmode 0. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Use WebTools or the CLI to perform the activate, clear all or delete opera- tions. Migration export to DCFM from EFCM can fail with an exception error. Fixed in DCFM 10.3.0 nl Workaround prior this version: nl Discover all the switches completely in EFCM before attempting the migra- tion. Event Policies Online Help dialog does not launch from the Brocade Message dialog. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Open online help from the Event Policies dialog, and then navigate to the Brocade Message dialog. Unable to launch Server Management Console (SMC) when the Windows domain is set as the primary authentication. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Kill the DCFM SMC process from the Task Manager. Names are not updated correctly and the name field is empty. Selecting OK in the resulting error message causes DCFM to become nl unresponsive. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Use the Port Mapping dialog for re- naming operations. If the switch configuration download fails, the switch should come back online. However, if it does not, DCFM continues to show the switch as online even though it is offline. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Bring the switch online manually. DCFM allows users to enter duplicate names in new server and storage fields when editing the Properties dialog. However, using the same names from the HBA Server Mapping dialog (right-click the server, and then click Server Port Mapping) fails. Fixed in DCFM 10.3.0 Importing names in the Names dialog takes a long time after migration, leading to DCFM becoming unresponsive. Fixed in DCFM 10.3.0 An obscure message, Switch WWN Change: User should have Chassis admin role is displayed as the discovery status for edge Fixed in DCFM 10.3.0 switch after migration from EFCM 9.7.x. Configure Logical Switches operation returns the error message Error fetching data from the Server for all Chassis. Fixed in DCFM 10.3.0 A search from the Product List works correctly, but a search from the tool bar does not. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Select Product List > Search. Several minutes after being added, new tunnels do not appear in the Connections window. Fixed in DCFM 10.3.0 nl Workaround prior to this version: nl Relaunch the DCFM client. B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Solution
Closed defect summary
Fixed in DCFM 10.3.0
Occasionally, a large database fails to be imported in interopmode
0 and interopmode 2, resulting in a violation error.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Use WebTools or the CLI to perform
the activate, clear all or delete opera-
tions.
Unable to activate, clear all, or delete a large zone database (1MB)
when in interopmode 0.
Fixed in DCFM 10.3.0
nl
Workaround prior this version:
nl
Discover all the switches completely
in EFCM before attempting the migra-
tion.
Migration export to DCFM from EFCM can fail with an exception error.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Open online help from the Event
Policies dialog, and then navigate to
the Brocade Message dialog.
Event Policies Online Help dialog does not launch from the Brocade
Message dialog.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Kill the DCFM SMC process from the
Task Manager.
Unable to launch Server Management Console (SMC) when the Win-
dows domain is set as the primary authentication.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Use the Port Mapping dialog for re-
naming operations.
Names are not updated correctly and the name field is empty. Selecting
OK
in the resulting error message causes DCFM to become
nl
unresponsive.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Bring the switch online manually.
If the switch configuration download fails, the switch should come back
online. However, if it does not, DCFM continues to show the switch
as online even though it is offline.
Fixed in DCFM 10.3.0
DCFM allows users to enter duplicate names in new server and storage
fields when editing the Properties dialog. However, using the same
names from the HBA Server Mapping dialog (right-click the server,
and then click
Server Port Mapping
) fails.
Fixed in DCFM 10.3.0
Importing names in the Names dialog takes a long time after migration,
leading to DCFM becoming unresponsive.
Fixed in DCFM 10.3.0
An obscure message,
Switch WWN Change: User should have
Chassis admin role
is displayed as the discovery status for edge
switch after migration from EFCM 9.7.
x
.
Fixed in DCFM 10.3.0
Configure Logical Switches operation returns the error message
Error
fetching data from the Server for all Chassis
.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Select
Product List
>
Search
.
A search from the Product List works correctly, but a search from the
tool bar does not.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Relaunch the DCFM client.
Several minutes after being added, new tunnels do not appear in the
Connections window.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional