HP Brocade 8/12c Brocade Network Advisor SMI Agent Developer's Guide - Page 154

that CEE indication is enabled in the switch.

Page 154 highlights

4 Alert indications TABLE 14 Supported alert indications (Continued) Message ID Trigger Property Value BRCD101 BRCD102 Fabric principal switch WWN changed. Query: SELECT * FROM CIM_AlertIndication WHERE OwningEntity=BROCADE and MessageID=BRCD101 AlertingManagedElement AlertingElementFormat AlertType OtherAlertType AlertSubType PerceivedSeverity ProbableCause SystemCreationClassName SystemName ProviderName OwningEntity Message MessageArguments SAN zone activation error. This alert indication is delivered for each fabric failure. Query: SELECT * FROM CIM_AlertIndication WHERE OwningEntity= BROCADE and MessageID=BRCD102 NOTE: This indication is delivered only if the operation is done through Brocade Network Advisor SMI Agent. AlertingManagedElement AlertingElementFormat AlertType OtherAlertType AlertSubType PerceivedSeverity ProbableCause SystemCreationClassName SystemName ProviderName OwningEntity Message MessageArguments COP of Brocade_Fabric COP Device Alert N/A Principal switch WWN changed 2 (Informational) 123 Brocade_Fabric Fabric WWN Brocade_AlertIndication Provider BROCADE Principal switch changed to old principal switch WWN new principal switch WWN COP of Brocade_Switch COP Other Zone alert SANZone activation failed 5 (Major) 123 Brocade_Fabric Fabric WWN Brocade_AlertIndication Provider Brocade SANZone activation failed for fabric Fabric WWN NOTE For indications from BRCD61 to BRCD76: All CEE alert indications and life-cycle indications are only applicable for FOS switches (Brocade 8000 switch and FCOE10-24 blade) with versions from v6.4.0. To get all CEE indications, make sure that CEE indication is enabled in the switch. 142 Brocade Network Advisor SMI Agent Developer's Guide 53-1002169-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

142
Brocade Network Advisor SMI Agent Developer’s Guide
53-1002169-01
Alert indications
4
NOTE
For indications from BRCD61 to BRCD76:
All CEE alert indications and life-cycle indications are only applicable for FOS switches (Brocade
8000 switch and FCOE10-24 blade) with versions from v6.4.0. To get all CEE indications, make sure
that CEE indication is enabled in the switch.
BRCD101
Fabric principal switch WWN changed.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD101
AlertingManagedElement
COP of Brocade_Fabric
AlertingElementFormat
COP
AlertType
Device Alert
OtherAlertType
N/A
AlertSubType
Principal switch WWN
changed
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Fabric
SystemName
Fabric WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Principal switch <WWN>
changed to <WWN>
MessageArguments
old principal switch WWN
new principal switch
WWN
BRCD102
SAN zone activation error. This alert
indication is delivered for each fabric
failure.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity= BROCADE and
MessageID=BRCD102
NOTE:
This indication is delivered only if
the operation is done through
Brocade Network Advisor SMI
Agent.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Other
OtherAlertType
Zone alert
AlertSubType
SANZone activation
failed
PerceivedSeverity
5 (Major)
ProbableCause
123
SystemCreationClassName
Brocade_Fabric
SystemName
Fabric WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
Brocade
Message
SANZone activation
failed for fabric <WWN>
MessageArguments
Fabric WWN
TABLE 14
Supported alert indications (Continued)
Message ID
Trigger
Property
Value