HP Cluster Platform Interconnects v2010 HP Cluster Platform ProLiant G6 and G7 - Page 62

Rear panel components, LEDs, and buttons (SL165z G7), PCI expansion slot definitions (SL165z G7)

Page 62 highlights

Item 2 3 4 5 6 7 Description Management connector activity LED (iLO) Management connector link LED (iLO) NIC activity LED NIC speed LED Power button/LED Health LED Status Flashing amber = LAN is active. Green = Linking at 100 Mbps speed Off = No connection exists, or linking at 10 Mbps speed. Flashing green = Network data activity exists. Off = No network data activity exists, or no network connection exists. Green = The LAN connection is using a GbE link. Amber = The LAN connection is using a 10 Mbps/100 Mbps link. Off = No LAN connection exists. Green = Normal. Amber = The server is powered off, or in a hibernation state with AC power. Red = Critical error Red = Critical system failure detected. Amber = The system is degraded. Green = The system is powered on, and no failure is detected. Off = The system is off, and no failure was detected prior to system power down. Rear panel components, LEDs, and buttons (SL165z G7) Item 1 2 3 Description UID LED/button Power supply cable connector 1 Power supply cable connector 2 PCI expansion slot definitions (SL165z G7) The HP ProLiant SL165z G6 Server has one x16 PCIe slot on the system board that supports an optional PCIe assembly. The PCIe assembly has two low-profile PCIe2 expansion slots. Slot Type 1 PCIe2 2 PCIe2 Length Half (low profile) Half (low profile) Connector x16 x8 Interconnect x16 x4 Always install an InfiniBand PCIe HCA in the low-profile x16 PCIe2 expansion slot on this server. HP ProLiant servers (scalable) 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

HP ProLiant servers (scalable)
62
Item
Description
Status
2
Management connector
activity LED (iLO)
Flashing amber = LAN is active.
3
Management connector link
LED (iLO)
Green = Linking at 100 Mbps speed
Off = No connection exists, or linking at 10 Mbps speed.
4
NIC activity LED
Flashing green = Network data activity exists.
Off = No network data activity exists, or no network connection exists.
5
NIC speed LED
Green = The LAN connection is using a GbE link.
Amber = The LAN connection is using a 10 Mbps/100 Mbps link.
Off = No LAN connection exists.
6
Power button/LED
Green = Normal.
Amber = The server is powered off, or in a hibernation state with AC
power.
Red = Critical error
7
Health LED
Red = Critical system failure detected.
Amber = The system is degraded.
Green = The system is powered on, and no failure is detected.
Off = The system is off, and no failure was detected prior to system
power down.
Rear panel components, LEDs, and buttons (SL165z G7)
Item
Description
1
UID LED/button
2
Power supply cable connector 1
3
Power supply cable connector 2
PCI expansion slot definitions (SL165z G7)
The HP ProLiant SL165z G6 Server has one x16 PCIe slot on the system board that supports an optional PCIe
assembly. The PCIe assembly has two low-profile PCIe2 expansion slots.
Slot
Type
Length
Connector
Interconnect
1
PCIe2
Half (low profile)
x16
x16
2
PCIe2
Half (low profile)
x8
x4
Always install an InfiniBand PCIe HCA in the low-profile x16 PCIe2 expansion slot on this server.