HP DL360 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide - Page 104

Hot-Plug Redundant Power Supply/PCI Switch (SW1) Settings, Debug LED Switch (SW3) Settings, Table E-5

Page 104 highlights

LEDs, Switches, and Jumpers Hot-Plug Redundant Power Supply/PCI Switch (SW1) Settings The hot-plug redundant power supply/PCI switch (SW1) is a four-position switch used for system maintenance. Refer to the labels attached to the inside of the server access panel for the proper switch settings. The following table shows the shipping configuration of SW1. Table E-5: Hot-Plug Redundant Power Supply/PCI Install Switch (SW1) Settings Position S1 S2 S3 S4 Function Reserved Reserved Reserved Identify PCI slot or Hot-Plug Redundant Power Supply support Default Off Off Off Off Description Reserved Reserved Reserved Off = Normal (PCI slot 2 supported) On = Hot-Plug Redundant power supply installed Debug LED Switch (SW3) Settings The Debug LED switch (SW3) is a four-position switch used for system maintenance. The positions on this switch are currently reserved and are not modified by the user. E-8 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

LEDs, Switches, and Jumpers
E-8
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
Hot-Plug Redundant Power Supply/PCI Switch (SW1) Settings
The hot-plug redundant power supply/PCI switch (SW1) is a four-position switch
used for system maintenance. Refer to the labels attached to the inside of the server
access panel for the proper switch settings. The following table shows the shipping
configuration of SW1.
Table E-5:
Hot-Plug Redundant Power Supply/PCI Install Switch (SW1) Settings
Position
Function
Default
Description
S1
Reserved
Off
Reserved
S2
Reserved
Off
Reserved
S3
Reserved
Off
Reserved
S4
Identify PCI slot or Hot-Plug
Redundant Power Supply
support
Off
Off = Normal (PCI slot 2 supported)
On = Hot-Plug Redundant power
supply installed
Debug LED Switch (SW3) Settings
The Debug LED switch (SW3) is a four-position switch used for system
maintenance. The positions on this switch are currently reserved and are not modified