Probe Test Procedure Follow the steps below to test the probe. 1. Discharged PIP Test Procedure: Turn the electrometer board ON (Via Systab I/O) as follows: a. Get the press to 'Stand-By' mode. b. Open the SysTab I/O Editor: Problem Handling > CE Applications > SysTab I/O Editor. At the SYSTAB- I/O find: 'ECN_ELECTROMETER POWER', double-click to activate it and set it as 'Hard Override'. c. In Systab I/O, set the electrometer board power to ON by typing [-1] in the Set field and press Set to activate it. 14 Chapter 2 Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

Probe Test Procedure
Follow the steps below to test the probe.
1.
Discharged PIP Test Procedure:
Turn the electrometer board
ON
(Via Systab I/O) as follows:
a.
Get the press to ‘
Stand-By
’ mode.
b.
Open the SysTab I/O Editor:
Problem Handling > CE Applications > SysTab I/O Editor
. At the SYSTAB-
I/O find:
'ECN_ELECTROMETER POWER’
, double-click to activate it and set it as ‘Hard Override’.
c.
In Systab I/O, set the electrometer board power to
ON
by typing [-1] in the
Set
field and press
Set
to
activate it.