HP Indigo 7800 Electrometer Board Test - Page 16
Probe Test Procedure
View all HP Indigo 7800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Probe Test Procedure Follow the steps below to test the probe. 1. Discharged PIP Test Procedure: Turn the electrometer board ON (Via Systab I/O) as follows: a. Get the press to 'Stand-By' mode. b. Open the SysTab I/O Editor: Problem Handling > CE Applications > SysTab I/O Editor. At the SYSTAB- I/O find: 'ECN_ELECTROMETER POWER', double-click to activate it and set it as 'Hard Override'. c. In Systab I/O, set the electrometer board power to ON by typing [-1] in the Set field and press Set to activate it. 14 Chapter 2 Procedures
Probe Test Procedure
Follow the steps below to test the probe.
1.
Discharged PIP Test Procedure:
Turn the electrometer board
ON
(Via Systab I/O) as follows:
a.
Get the press to ‘
Stand-By
’ mode.
b.
Open the SysTab I/O Editor:
Problem Handling > CE Applications > SysTab I/O Editor
. At the SYSTAB-
I/O find:
'ECN_ELECTROMETER POWER’
, double-click to activate it and set it as ‘Hard Override’.
c.
In Systab I/O, set the electrometer board power to
ON
by typing [-1] in the
Set
field and press
Set
to
activate it.
14
Chapter 2
Procedures