Turn OFF the Charge Roller AC voltage from the SYSTAB-I/O Editor. At the SYSTAB-I/O find, Voltage
View all HP Indigo 7800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
8. Stop the charge roller: a. Turn OFF the Charge Roller DC voltage as follows: From the press UI: (Element Activation > Charge Roller Tab), touch the Voltage button. b. Turn OFF the Charge Roller AC voltage from the SYSTAB-I/O Editor. At the SYSTAB-I/O find: 'IO_HVIF_CR_AC_SETV', double-click to activate it and set it to 0 (zero). After setting the value above, verify that 'Formulated value' for IO_HVIF_CR_DC_SETV = 0. Probe Test Procedure 23
8.
Stop the charge roller:
a.
Turn
OFF
the Charge Roller DC voltage as follows: From the press UI: (
Element Activation > Charge
Roller Tab),
touch the
Voltage
button.
b.
Turn OFF the Charge Roller AC voltage from the SYSTAB-I/O Editor. At the SYSTAB-I/O find:
‘
IO_HVIF_CR_AC_SETV’
, double-click to activate it and set it to 0 (zero).
After setting the value above, verify that ‘Formulated value’ for IO_HVIF_CR_DC_SETV =
0
.
Probe Test Procedure
23