From press UI: Element Activation > Liquids tab, touch the CS, Pump., Cleaning station, Disengage
View all HP Indigo 7800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
f. Deactivate the cleaning station oil pump. i. From press UI: Element Activation > Liquids tab, touch the CS Pump. ii. In the Motors Tab, touch the Cleaning station button to deactivate the cleaning station. g. Disengage the PIP drum. From the press UI: (Element Activation > Drums Tab > PIP), press Disengage. h. Stop the motor by clicking the motor button. See step d above for reference. 2. Charged PIP Test Procedure: Turn the electrometer board ON (Via Systab I/O) as follows: a. Get the press to 'Stand-By' mode. Probe Test Procedure 17
f.
Deactivate the cleaning station oil pump.
i.
From press UI: Element Activation > Liquids tab, touch the CS
Pump.
ii.
In the Motors Tab, touch the
Cleaning station
button to deactivate the cleaning station.
g.
Disengage the PIP drum. From the press UI: (
Element Activation > Drums Tab > PIP
), press
Disengage
.
h.
Stop the motor by clicking the motor button. See step
d
above for reference.
2.
Charged PIP Test Procedure:
Turn the electrometer board
ON
(Via Systab I/O) as follows:
a.
Get the press to ‘
Stand-By
’ mode.
Probe Test Procedure
17