HP Indigo WS6000 Preventive Maintenance -- CA393-00660 Rev 08 - Page 21

Visually check all cables and connections for wear and tear.

Page 21 highlights

4. Using IPA, clean inside the Corona unit. 5. Reinstall the Corona electrode in the Corona unit. Corona electrode in Corona unit. 6. Using IPA, wipe the outside of the Corona unit. 7. At the rear of the ILP, access the generator, Using low air pressure, blow compressed air into the generator. 8. Visually check all cables and connections for wear and tear. CAUTION: Worn cables can cause an electric shock. Make sure that the ILP power is off. Appendix D - Corona Maintenance 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

4.
Using IPA, clean inside the Corona unit.
5.
Reinstall the Corona electrode in the Corona unit. Corona electrode in Corona unit.
6.
Using IPA, wipe the outside of the Corona unit.
7.
At the rear of the ILP, access the generator, Using low air pressure, blow compressed air into the
generator.
8.
Visually check all cables and connections for wear and tear.
CAUTION:
Worn cables can cause an electric shock. Make sure that the ILP power is off.
Appendix D - Corona Maintenance
19