HP Indigo WS6000 Preventive Maintenance -- CA393-00660 Rev 08 - Page 9

Ink Cabinet, HP Indigo WS6600 Digital Press Installation Manual, Component, Procedure

Page 9 highlights

Component Cleaning station Charge roller Ink cabinet General inspection Procedure ● Remove the cleaning station assembly, and clean it. ● Replace sponge roller (If needed). ● Check parts for wear (replace if needed). ● Cleaning the orifice at the CS pump exit. ● Change wiper sides. ● Inspect the CS timing belt and replace if needed. ● Inspect the V-seal O-ring and replace if needed. ● Clean the balancing roller. ● Replace the charge roller (If needed). ● Clean housing and carbon brushes using IPA. ● Remove if needed and clean the electrometer. ● Clean the imaging agent injection system. See the Ink Cabinet service document (CA393-04290). ● Clean all the Ink pumps. ● Clean the Density and Conductivity sensors. ● Ink calibrations: - Density - Conductivity - Ink flow ● Clean all the BIDs, wipe the Developer using a lint-free wipe with IMO ● Press leveling and alignment, follow instructions in HP Indigo WS6600 Digital Press Installation Manual (CA393-04361) or HP Indigo W7200 Digital Press Installation Manual (CA393-01570). ● Perform the dripping baseline procedure in CA393-03500 ● Clean the ILD lens using a lint free wipe with IPA, and use a clean dry wipe to clean off any residue from the IPA. ● Check the condition of the sealing materials in the following, and replace if needed: - Catch tray - ITM hood ● Clean the Ceramic Tiles using a lint free wipe with IPA, and use a clean dry wipe to clean off any residue from the IPA. ● Wipe the Air Knife/PTE with a lint-free wipe with IPA ● Wipe the E/H lamp using a lint-free wipe with IPA. ● Check that the GLS (grease and lubrication system) is functioning, verify that the gears are greased properly. CE Preventive Maintenance Tasks 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Component
Procedure
Cleaning station
Remove the cleaning station assembly, and clean it.
Replace sponge roller (If needed).
Check parts for wear (replace if needed).
Cleaning the orifice at the CS pump exit.
Change wiper sides.
Inspect the CS timing belt and replace if needed.
Inspect the V-seal O-ring and replace if needed.
Charge roller
Clean the balancing roller.
Replace the charge roller (If needed).
Clean housing and carbon brushes using IPA.
Remove if needed and clean the electrometer.
Ink cabinet
Clean the imaging agent injection system. See the
Ink Cabinet
service document (CA393-04290).
Clean all the Ink pumps.
Clean the Density and Conductivity sensors.
Ink calibrations:
Density
Conductivity
Ink flow
General inspection
Clean all the BIDs, wipe the Developer using a lint-free wipe with IMO
Press leveling and alignment, follow instructions in
HP Indigo WS6600 Digital Press Installation Manual
(CA393-04361) or
HP Indigo W7200 Digital Press Installation Manual
(CA393-01570).
Perform the dripping baseline procedure in CA393-03500
Clean the ILD lens using a lint free wipe with IPA, and use a clean dry wipe to clean off any residue from
the IPA.
Check the condition of the sealing materials in the following, and replace if needed:
Catch tray
ITM hood
Clean the Ceramic Tiles using a lint free wipe with IPA, and use a clean dry wipe to clean off any residue
from the IPA.
Wipe the Air Knife/PTE with a lint-free wipe with IPA
Wipe the E/H lamp using a lint-free wipe with IPA.
Check that the GLS (grease and lubrication system) is functioning, verify that the gears are greased
properly.
CE Preventive Maintenance Tasks