HP Integrity Superdome 2 16-socket HP Integrity Superdome 2 Onboard Administra - Page 139
Superdome 2 Enclosure fan location rules, Fan Information - Bay screen
View all HP Integrity Superdome 2 16-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Fan speeds appear in percentage of total capacity, and fans operating in a zone without any blades run at a minimum RPM of 30% to maintain proper cooling in the entire enclosure. Item Thermal Zone Zone Speed Device Bays Fan Bay Fan Status Fan Speed Description The six cooling zones in the enclosure: upper left, upper right, middle left, middle right, lower left, and lower right. The computed fan speed required based on the highest device need in the zone. The number of the device bays in a particular thermal zone. The fan bay number. Fans in bays 3, 8, and 13 are shared between thermal zones. The overall status of each fan. Possible values are Unknown, OK, Degraded, Failed, and Absent. The fan speed is displayed as a percentage of maximum RPM. Superdome 2 Enclosure fan location rules The HP Integrity Superdome 2 Enclosure ships with 15 HP Active Cool fans. All 15 fans are required for optimum cooling of all device bays, GSPM bays, XFM bays and interconnect bay components. 15 Fan Rule All fan bays are used to support a maximum of 16 devices in the device bays. This includes eight HP Integrity Superdome 2 Server Blades. Fan Information - Bay screen Selecting a specific fan opens the Fan Information-Bay x screen, where x is the bay of the selected Fan. This screen provides status information on the selected fan. Enclosure power management 139