HP Integrity Superdome 2 16-socket HP Integrity Superdome 2 Onboard Administra - Page 51
Power Management screen, For possible values and descriptions of each box, see
View all HP Integrity Superdome 2 16-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
For possible values and descriptions of each box, see "SNMP Settings screen" (page 94). Power Management screen IMPORTANT: In a complex with one or more failed power supplies, it is possible for attempts to power on servers to fail if the resulting power allocation would result in the Power Redundancy Status becoming Failed. The administrator must explicitly reduce the redundancy setting to enable powering on servers prior to the failed power supplies being serviced. This applies to AC Redundant and Power Supply Redundant power modes. NOTE: If redundancy mode is set to Redundant, AC Redundant, or Power Supply Redundant, and power redundancy is lost, then you must either add additional power supplies or change the redundancy mode setting in the Onboard Administrator to restore Power Subsystem status. One upper and one lower power supply must always be installed and operational. For corrective steps, see the Insight Display. Power Management screen 51