HP Integrity Superdome 2 32-socket HP Integrity Superdome 2 Onboard Administra - Page 114
Port Mapping Information, Status information, Diagnostic Information
View all HP Integrity Superdome 2 32-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
Port Mapping Information Information regarding port mapping for all devices in the device bay is available by clicking the Port Mapping Information link. Status information Item Status Powered Power Allocated Ambient Temperature Ambient Caution Threshold Ambient Critical Threshold Partner Device Description The overall status of the blade. Possible values are Unknown, OK, Degraded, Failed, or Other with an informational icon. The informational icon with an Other status displays until the server blade is configured for Virtual Connect Manager. See the Diagnostic Information table for more information. The power state of the blade. Possible values are On or Off. The amount of power allocated to the blade in watts. The temperature of the blade in degrees Celsius and Fahrenheit. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The temperature thresholds at which the server blade displays a degraded status because of a thermal condition. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The temperature thresholds at which the server blade powers off because of a degraded thermal condition. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The storage blade the server blade is partnered with. This information does not display if there is no partner device. NOTE: Not applicable for HP Integrity Superdome 2 server blades. Diagnostic Information Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has occurred) or is sent by the device microcontroller, without being polled to report a failure. Item Device Identification Data Management Processor Temperature Overheat Check I/O Configuration Power Allocation Request Cooling Description Contains information on model name, part number, serial number, and other information used to identify the device. This data is also called FRU data. Device identification data error displays if the data is not present or not readable by the Onboard Administrator. Status of the iLO. Possible values are OK or Error. Temperature is above the warning threshold. Possible values are OK or Temperature Warning. Temperature is above the danger threshold. Possible values are OK or Critical temperature threshold reached. Device bay configuration is incorrect. If a storage blade is partnered with a full height server blade, and the server blade does not have the correct mezzanine card, an invalid I/O configuration will result. Possible values are OK or I/O mismatch detected. See the EBIPA section for more information. There is insufficient power to adequately power this server blade. Possible values are OK or Insufficient enclosure power. There are an insufficient number of fans to properly cool this server blade or the fan configuration is incorrect. Possible values are OK or Insufficient fans for enclosure cooling. 114 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices