HP Integrity Superdome 2 32-socket HP Integrity Superdome 2 Onboard Administra - Page 120
Interconnect Bay Status tab, Status information, Diagnostic Information
View all HP Integrity Superdome 2 32-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
Interconnect Bay Status tab Status information Item Status Thermal Status Powered Description The overall status of the interconnect device. Possible values are Unknown, OK, Degraded, and Failed. The thermal status of the interconnect device. Possible values are Unknown, OK, Degraded, and Failed. The power state of the interconnect device. Possible values are On or Off. Diagnostic Information Row Device Identification Data Management Processor Temperature Overheat Check Device Operational Device Degraded Description Contains information on model name, part number, serial number, and other information used to identify the device. This data is also called FRU data. Device identification data error displays if the data is not present or not readable by the Onboard Administrator. Management processor is not responding. Possible values are OK or Error. Temperature is above the warning threshold. Possible values are OK or Temperature Warning. Temperature is above the danger threshold. Possible values are OK or Critical temperature threshold reached. Device has failed; status was not requested by the Onboard Administrator. Possible values are OK or Error. Device has failed; status was requested by the Onboard Administrator. Possible values are OK or Error. 120 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices