HP Integrity rx2620 Windows Integrity Management Agents Reference - Page 116
Check IO backplane power board. Faulted VRM, is given by PS command.
![]() |
View all HP Integrity rx2620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
11530 11531 11537 11538 11566 11567 11568 11569 11575 11576 11578 11579 11580 11581 11582 11583 11584 The user has configured an fPar to be booted with Reconfigure the fPar, giving it at least inadequate memory resources to instantiate the instance-size (an fPars EFI variable) amount of firmware image for this fPar. The fPar is software physically contiguous RAM. Then re-enable and deconfigured (disabled) from booting. reset the fPar. The fPar has been enabled to boot, and contains at least one CPU and adequate memory but has not been given any IO resources. The soft partition (fPar) may therefore only boot as far as Reconfigure the soft partition using an the EFI shell. It must be reconfigured and reset Operating-system-specific utility then reset the before it may boot an operating system. soft partition. All CPUs were scheduled to be deconfigured through a combination of user deconfigures and/or failures No action is required. Either all CPUs were slated for deconfiguration, or NVM has been cleared, or a new CPU type has been installed. No action is required. One of the 3.3v VRM's is reporting a fault, one failure and power state is N, after two power state Check IO backplane power board faulted VRM will be N-. is give by PS command. One of the 5.0v VRM's is reporting a fault, one failure and power state is N, after two power state check IO backplane power board faulted VRM is will be N-. give by PS command. One of the -12v VRM's is reporting a fault, one failure and power state is N, after two power state Check IO backplane power board faulted VRM will be N-. is give by PS command. One of the +12v VRM's is reporting a fault. One failure and power state is N, after two power state Check IO backplane power board. Faulted VRM will be N-. is given by PS command. One of the 1.5v VRM's is over temp. Check IO backplane power board faulted VRM is give by PS command. One of the 3.3v VRM's is over temp. Check IO backplane power board faulted VRM is give by PS command. One of the -12v VRM's is over temp. Check IO backplane power board faulted VRM is give by PS command. One of the +12v VRM's is over temp and has shutdown. One failure and the Redundancy state is 'not redundant', after two power faults the Check IO backplane power board. Faulted VRM redundancy state is 'insufficient'. is given by PS command. An error occurred while routing the fabric. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. Firmware was unable to find a valid route to a cell being added by OLA. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. An error occurred while routing the fabric. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. An error occurred while routing the fabric. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. An error occurred while routing the fabric Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. 116 Management Agents Event Tables
![](/manual_guide/products/hewlettpackard-rx26202-windows-integrity-management-agents-reference-eaaeda1/116.png)