HP Integrity rx3600 HP Insight Manager WBEM Provider Events Reference - Page 32
MC_RENDEZVOUS: Set PAL features failed. Probable Cause: PAL does not support - user service guide
View all HP Integrity rx3600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Event ID Event Severity 5686 Warning 5692 Error 5696 Error 5698 Error 5700 Error 5701 Warning 5704 Warning 5708 Error 5711 Warning 5712 Warning 5713 Error 5714 Error 5715 Error Event Description MC_RENDEZVOUS: Set PAL features failed. Probable Cause: PAL does not support call to set the processor feature set during processor rendezvous Recommended Action: update system firmware with new PAL that support the PAL_SET_FEATURE call. WBEM EventID: 452. WBEM ProviderName: FPL_IndicationProvider. Internal Firmware Programming Error from the EFI portion of the firmware. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. WBEM EventID: 453. WBEM ProviderName: FPL_IndicationProvider. memory extender loading order error. Probable Cause: The memory extenders have not been loaded in the correct order. Recommended Action: Load the Memory extenders according to the users manual. WBEM EventID: 454. WBEM ProviderName: FPL_IndicationProvider. Inconsistency in the length of the ESI table. Probable Cause: Table entries corrupted. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 455. WBEM ProviderName: FPL_IndicationProvider. The computed checksum for ESI Table incorrect. Probable Cause: Table corrupted. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 456. WBEM ProviderName: FPL_IndicationProvider. ESI Table contains an unsupported entry type. Probable Cause: Corrupted table. Recommended Action: Reboot system. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 457. WBEM ProviderName: FPL_IndicationProvider. A GUID was larger than the expected 128 bits. Probable Cause: Inconsistency in EFI firmware. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 458. WBEM ProviderName: FPL_IndicationProvider. EFI is halting. Probable Cause: Unknown. Recommended Action: examine preceding events for problem. WBEM EventID: 459. WBEM ProviderName: FPL_IndicationProvider. chipspare not supported on quad. Probable Cause: User installed a x8 DIMM in a system configured for chipspare. Recommended Action: If user requires Chipspare, replace the DIMM with a x4 DIMM. If Chipspare is not required, then no action is required. WBEM EventID: 460. WBEM ProviderName: FPL_IndicationProvider. EFI internal error detected resulting in execution of ASSERT macro. Probable Cause: The cause is unknown. Recommended Action: Look at previous events and ASCII information in this event for more information. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 461. WBEM ProviderName: FPL_IndicationProvider. EFI has executed the 'break' shell command. Probable Cause: Executing the 'break' command. Recommended Action: Check for user entering 'break' command. Check for shell scripts using the 'break' command. WBEM EventID: 462. WBEM ProviderName: FPL_IndicationProvider. EFI USB HCD interrupt service has detected the host controller is hung. Probable Cause: Problem with USB controller. Recommended Action: Reset the card containing the USB interface to restart the controller. Contact your HP representative to check the USB interface. WBEM EventID: 463. WBEM ProviderName: FPL_IndicationProvider. The EFI/SAL handoff structure's version does not match EFI expectations. Probable Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 464. WBEM ProviderName: FPL_IndicationProvider. 32 WBEM Provider Event Tables