HP Integrity rx3600 HP Insight Manager WBEM Provider Events Reference - Page 57
Failed clearing of the XIN_ERR_ORDER_STATUS CSR. Probable Cause: Failure
View all HP Integrity rx3600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Event ID Event Severity 8858 Warning 8859 Warning 8860 Warning 8861 Warning 8864 Warning 8865 Warning 8872 Error 8873 Error 8876 Warning 8877 Warning 8882 Warning 8883 Warning 8894 Warning 8895 Warning 8896 Warning 8897 Warning Event Description This means that all the cells did not rendezvous during the PD rendezvous. Probable Cause: The cells will reset themselves. WBEM EventID: 839. WBEM ProviderName: FPL_IndicationProvider. The FW tree sanity check failed during the MCA error processing. Probable Cause: The cells will independently log errors and reset. WBEM EventID: 840. WBEM ProviderName: FPL_IndicationProvider. This means that the registry sanity check failed during MCA error handling. Probable Cause: The cells will independently log errors and reset. WBEM EventID: 841. WBEM ProviderName: FPL_IndicationProvider. This means that MCA occurred while OS_MCA was performing error recovery. Probable Cause: The cells will log information and reset. WBEM EventID: 842. WBEM ProviderName: FPL_IndicationProvider. One of the BT errors occurred that results in abandoning memory dump. Probable Cause: A machine check has occurred and cells have not rendezvoused. Recommended Action: Cells will reset themselves. WBEM EventID: 843. WBEM ProviderName: FPL_IndicationProvider. The firmware tree is not complete and hence there will be no PD rendezvous. Probable Cause: The cell will log errors and reset. WBEM EventID: 844. WBEM ProviderName: FPL_IndicationProvider. ACPI configuration mismatch across cells in the partition. Probable Cause: Set the ACPI configuration parameter again to ensure that all cells have a consistent value. WBEM EventID: 845. WBEM ProviderName: FPL_IndicationProvider. Failed clearing of the XIN_ERR_ORDER_STATUS CSR. Probable Cause: Failure to access the register or the write did not work. Recommended Action: Contact HP Support personnel to check the CC. WBEM EventID: 846. WBEM ProviderName: FPL_IndicationProvider. Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 848. WBEM ProviderName: FPL_IndicationProvider. Invalid data read from a CPU module's Processor Information ROM. Probable Cause: The CPU module's Processor Information ROM is unprogrammed. Recommended Action: Contact HP support personnel to troubleshoot the CPU module pointed to by the physical location portion of this event. WBEM EventID: 849. WBEM ProviderName: FPL_IndicationProvider. Invalid parameter when setting cpu frequency ratios. Probable Cause: Specify a valid parameter. WBEM EventID: 2444. WBEM ProviderName: FPL_IndicationProvider. Option block in nvram has a checksum error. Probable Cause: Clear NVRAM. WBEM EventID: 851. WBEM ProviderName: FPL_IndicationProvider. CC to CC link did not initialize on the local cell. Probable Cause: link failure between the XBC and the CC Recommended Action: Check CC. WBEM EventID: 852. WBEM ProviderName: FPL_IndicationProvider. Failed to write the CC link disable register. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 853. WBEM ProviderName: FPL_IndicationProvider. An unknown backplane type was found. Probable Cause: CSR Read/Write error Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 854. WBEM ProviderName: FPL_IndicationProvider. Error writing the CC link error mask. Probable Cause: Fabric Access Error. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 855. WBEM ProviderName: FPL_IndicationProvider. Platform Events 57