Event ID Event Severity 11710 Error 11711 Error 11712 Error 11718 Error 11719 Error 11720 Error 11721 Error 11723 Error 11724 Error 11775 Warning 11780 Warning 11783 Warning 11784 Error Event Description Could not create a file system node for communication between the vmm driver and the virtual machine. The next event contains the error from the Unix system call. Probable Cause: Insufficient resources or file system problem Recommended Action: Verify that the root file system has no errors and is not full. WBEM EventID: 5143. WBEM ProviderName: FPL_IndicationProvider. The vm device was created but cannot be opened. Probable Cause: File system error or PMAN has insufficient resources Recommended Action: Verify that the root file system has no errors and that the PMAN has sufficient memory. WBEM EventID: 5144. WBEM ProviderName: FPL_IndicationProvider. The virtual machine driver has not been loaded. Probable Cause: HPVM has not been started Recommended Action: Start HPVM. WBEM EventID: 5145. WBEM ProviderName: FPL_IndicationProvider. An attempt to create a thread on the PMAN has failed. The next event contains the Unix error number. Probable Cause: Insufficient resources Recommended Action: Reduce guest resources or add memory. WBEM EventID: 5146. WBEM ProviderName: FPL_IndicationProvider. VM Driver was unable to communicate with virtual machine. Probable Cause: This is an internal error. Recommended Action: If this continues to occur, reinstall the software. If this does not fix the problem contact your HP support representative. WBEM EventID: 5147. WBEM ProviderName: FPL_IndicationProvider. The configuration file could not be read. Probable Cause: The configuration file is missing or damaged. Recommended Action: Restore the configuration from a backup or recreate the guest. WBEM EventID: 5148. WBEM ProviderName: FPL_IndicationProvider. Memory allocation for a firmware table has failed. The data contains the name of the firmware table. Probable Cause: Insufficient memory available Recommended Action: Increase available memory or swap file space. WBEM EventID: 5149. WBEM ProviderName: FPL_IndicationProvider. Driver was unable to build map tables. Probable Cause: Insufficient resources or PMAN kernel memory too fragmented Recommended Action: Add memory or reboot. WBEM EventID: 5150. WBEM ProviderName: FPL_IndicationProvider. Reboot failed. The virtual machine will exit. Probable Cause: The virtual machine was unable to restart. The next event contains the Unix error. Recommended Action: Restart if possible. WBEM EventID: 5151. WBEM ProviderName: FPL_IndicationProvider. SetupInitialCohTables() returned an error. Data field: (cell set 32) | (return value from SetupInitialCohTables()). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4978. WBEM ProviderName: FPL_IndicationProvider. Stable store read or write to flash failed. Probable Cause: Soft error Flash part Failure Recommended Action: Reboot, if problem persists, contact HP support. WBEM EventID: 5152. WBEM ProviderName: FPL_IndicationProvider. Error reading or writing the stable store NVM area. Probable Cause: A read/write to the NVM stable storage area failed Recommended Action: Reboot, if problem persists, contact HP support. WBEM EventID: 5153. WBEM ProviderName: FPL_IndicationProvider. FW has detected an illegal memory config using 4GB DIMMs. The system will be halted. Probable Cause: An unsupported memory configuration with 4GB DIMMs is installed in the system Recommended Action: Refer to the user documentation to determine the supported memory configurations with 4GB DIMMs. WBEM EventID: 5154. WBEM ProviderName: FPL_IndicationProvider. Platform Events 93