HP Integrity rx3600 HP Insight Manager WBEM Provider Events Reference - Page 93

Unix error number. Probable Cause: Insufficient resources Recommended Action

Page 93 highlights

Event ID Event Severity 11710 Error 11711 Error 11712 Error 11718 Error 11719 Error 11720 Error 11721 Error 11723 Error 11724 Error 11775 Warning 11780 Warning 11783 Warning 11784 Error Event Description Could not create a file system node for communication between the vmm driver and the virtual machine. The next event contains the error from the Unix system call. Probable Cause: Insufficient resources or file system problem Recommended Action: Verify that the root file system has no errors and is not full. WBEM EventID: 5143. WBEM ProviderName: FPL_IndicationProvider. The vm device was created but cannot be opened. Probable Cause: File system error or PMAN has insufficient resources Recommended Action: Verify that the root file system has no errors and that the PMAN has sufficient memory. WBEM EventID: 5144. WBEM ProviderName: FPL_IndicationProvider. The virtual machine driver has not been loaded. Probable Cause: HPVM has not been started Recommended Action: Start HPVM. WBEM EventID: 5145. WBEM ProviderName: FPL_IndicationProvider. An attempt to create a thread on the PMAN has failed. The next event contains the Unix error number. Probable Cause: Insufficient resources Recommended Action: Reduce guest resources or add memory. WBEM EventID: 5146. WBEM ProviderName: FPL_IndicationProvider. VM Driver was unable to communicate with virtual machine. Probable Cause: This is an internal error. Recommended Action: If this continues to occur, reinstall the software. If this does not fix the problem contact your HP support representative. WBEM EventID: 5147. WBEM ProviderName: FPL_IndicationProvider. The configuration file could not be read. Probable Cause: The configuration file is missing or damaged. Recommended Action: Restore the configuration from a backup or recreate the guest. WBEM EventID: 5148. WBEM ProviderName: FPL_IndicationProvider. Memory allocation for a firmware table has failed. The data contains the name of the firmware table. Probable Cause: Insufficient memory available Recommended Action: Increase available memory or swap file space. WBEM EventID: 5149. WBEM ProviderName: FPL_IndicationProvider. Driver was unable to build map tables. Probable Cause: Insufficient resources or PMAN kernel memory too fragmented Recommended Action: Add memory or reboot. WBEM EventID: 5150. WBEM ProviderName: FPL_IndicationProvider. Reboot failed. The virtual machine will exit. Probable Cause: The virtual machine was unable to restart. The next event contains the Unix error. Recommended Action: Restart if possible. WBEM EventID: 5151. WBEM ProviderName: FPL_IndicationProvider. SetupInitialCohTables() returned an error. Data field: (cell set 32) | (return value from SetupInitialCohTables()). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4978. WBEM ProviderName: FPL_IndicationProvider. Stable store read or write to flash failed. Probable Cause: Soft error Flash part Failure Recommended Action: Reboot, if problem persists, contact HP support. WBEM EventID: 5152. WBEM ProviderName: FPL_IndicationProvider. Error reading or writing the stable store NVM area. Probable Cause: A read/write to the NVM stable storage area failed Recommended Action: Reboot, if problem persists, contact HP support. WBEM EventID: 5153. WBEM ProviderName: FPL_IndicationProvider. FW has detected an illegal memory config using 4GB DIMMs. The system will be halted. Probable Cause: An unsupported memory configuration with 4GB DIMMs is installed in the system Recommended Action: Refer to the user documentation to determine the supported memory configurations with 4GB DIMMs. WBEM EventID: 5154. WBEM ProviderName: FPL_IndicationProvider. Platform Events 93

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Could not create a file system node for communication between the vmm driver and
the virtual machine. The next event contains the error from the Unix system call.
Probable Cause: Insufficient resources or file system problem Recommended Action:
Verify that the root file system has no errors and is not full. WBEM EventID: 5143.
WBEM ProviderName: FPL_IndicationProvider.
Error
11710
The vm device was created but cannot be opened. Probable Cause: File system error
or PMAN has insufficient resources Recommended Action: Verify that the root file
system has no errors and that the PMAN has sufficient memory. WBEM EventID:
5144. WBEM ProviderName: FPL_IndicationProvider.
Error
11711
The virtual machine driver has not been loaded. Probable Cause: HPVM has not been
started Recommended Action: Start HPVM. WBEM EventID: 5145. WBEM
ProviderName: FPL_IndicationProvider.
Error
11712
An attempt to create a thread on the PMAN has failed. The next event contains the
Unix error number. Probable Cause: Insufficient resources Recommended Action:
Reduce guest resources or add memory. WBEM EventID: 5146. WBEM ProviderName:
FPL_IndicationProvider.
Error
11718
VM Driver was unable to communicate with virtual machine. Probable Cause: This
is an internal error. Recommended Action: If this continues to occur, reinstall the
software. If this does not fix the problem contact your HP support representative.
WBEM EventID: 5147. WBEM ProviderName: FPL_IndicationProvider.
Error
11719
The configuration file could not be read. Probable Cause: The configuration file is
missing or damaged. Recommended Action: Restore the configuration from a backup
or recreate the guest. WBEM EventID: 5148. WBEM ProviderName:
FPL_IndicationProvider.
Error
11720
Memory allocation for a firmware table has failed. The data contains the name of the
firmware table. Probable Cause: Insufficient memory available Recommended Action:
Increase available memory or swap file space. WBEM EventID: 5149. WBEM
ProviderName: FPL_IndicationProvider.
Error
11721
Driver was unable to build map tables. Probable Cause: Insufficient resources or
PMAN kernel memory too fragmented Recommended Action: Add memory or
reboot. WBEM EventID: 5150. WBEM ProviderName: FPL_IndicationProvider.
Error
11723
Reboot failed. The virtual machine will exit. Probable Cause: The virtual machine
was unable to restart. The next event contains the Unix error. Recommended Action:
Restart if possible. WBEM EventID: 5151. WBEM ProviderName:
FPL_IndicationProvider.
Error
11724
SetupInitialCohTables() returned an error. Data field: (cell set 32) | (return value
from SetupInitialCohTables()). Probable Cause: An error occurred while routing the
fabric. Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 4978.
WBEM ProviderName: FPL_IndicationProvider.
Warning
11775
Stable store read or write to flash failed. Probable Cause: Soft error Flash part Failure
Recommended Action: Reboot, if problem persists, contact HP support. WBEM
EventID: 5152. WBEM ProviderName: FPL_IndicationProvider.
Warning
11780
Error reading or writing the stable store NVM area. Probable Cause: A read/write to
the NVM stable storage area failed Recommended Action: Reboot, if problem persists,
contact HP support. WBEM EventID: 5153. WBEM ProviderName:
FPL_IndicationProvider.
Warning
11783
FW has detected an illegal memory config using 4GB DIMMs. The system will be
halted. Probable Cause: An unsupported memory configuration with 4GB DIMMs
is installed in the system Recommended Action: Refer to the user documentation to
determine the supported memory configurations with 4GB DIMMs. WBEM EventID:
5154. WBEM ProviderName: FPL_IndicationProvider.
Error
11784
Platform Events