hp Integrity rx5670 Site Preparation Guide Product ID: A6837B/A6838B Manufacturing Part Number : rx5670_SitePrep July 2003 U.S.A. © Copyright 2003, Hewlett-Packard Development Company, L.P. - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 2
The HP Server Documentation CD-ROM has been provided with your server. It contains a complete documentation set for the server, including localized versions of key documents. Included on the CD-ROM are the Site Preparation and Operations and Maintenance guides, which contain in-depth troubleshooting - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 3
Power Requirements 8 Environmental Specifications 9 Temperature and Humidity Specifications 9 Acoustic Noise Specification 9 Air Flow 9 Loading 26 Windows 28 Space Requirements 29 Delivery Space Requirements 29 Operational Space Requirements 29 Floor Plan Grid 29 Conversion Factors and - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 4
Contents Power Cable 43 Glossary 45 4 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 5
1 System Specifications System Configuration The following table lists the minimum and maximum configurations for an hp Integrity rx5670. Table 1-1 Minimum/Maximum Configuration System Name CPUs Power Supplies Memory Extenders DIMM Sets (4 DIMMs per set) Optional Internal Disks Optional - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 6
System Specifications Dimensions and Weights Dimensions and Weights This section provides dimensions and weights of hp Integrity rx5670 components. Component Dimensions Table 1-2 Server Component Dimensions Component Width (cm) Depth/ Length (cm) Height (cm) Maximum Quantity per Cabinet - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 7
Specifications Electrical Specifications Electrical Specifications This section provides electrical specifications for the system. Circuit Breaker The Marked Electrical for the HP Server two power supplies/cords must be used to maintain normal operation of the system. A third power supply/cord can - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 8
System Specifications Electrical Specifications Component Power Requirements Table 1-5 Typical Power Consumptiona CPU's DIMM's consumption for facility installation. Typical power consumption numbers are what HP engineers have measured running power intensive applications. These are generally - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 9
room environments, not office environments. Care should be taken to understand the acoustic noise specifications relative to operator positions within the computer room or when adding HP Servers to computer rooms with existing noise sources. Air Flow The recommended cabinet air intake temperature - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 10
System Specifications Environmental Specifications 10 Chapter 1 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 11
operation of an hp Integrity rx5670. Electrical Factors NOTE Electrical practices and suggestions in this guide specific or area-specific electrical codes and guidelines. Proper design and installation of a power distribution system for an hp Integrity rx5670 most trouble-free operation. servicing - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 12
during equipment servicing. Safer servicing is Space for Server Access The recommended working space for performing maintenance on the server is hp Integrity rx5670 is designed to operate over a wide range of voltages and frequencies. The server is tested and shown to comply with EMC Specification - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 13
, affect the quality of electrical power. Common sources of these disturbances are: • Fluctuations occurring within the facility's distribution system • Utility service low-voltage conditions (such as sags or brownouts) • Wide and rapid variations in input voltage levels • Wide and rapid variations - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 14
cannot conclusively rule out loss of service. Therefore, adherence to the following guidelines provides the best possible performance of power distribution systems for HP computer equipment: • Dedicated power source-Isolates an hp Integrity rx5670 power distribution system from other circuits - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 15
no direct connection to earth according to IEC 60950). An hp Integrity rx5670 requires two methods of grounding: • Power distribution safety grounding to all points. Main Building Electrical Ground The main electrical service entrance equipment should have an earth ground connection, as required - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 16
General Site Preparation Guidelines Electrical Factors NOTE In some cases power distribution system green (green/yellow) wire ground conductors are too long and inductive to provide adequate high frequency ground return paths. Therefore, a ground strap (customer-supplied) should be used for - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 17
a ground grid with bolted down stringers and corrosion resistive plating (to provide low resistance and attachment points for connection to service entrance ground and HP computer equipment). The use of conductive floor tiles with this style of grid further enhances ground performance. The structure - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 18
General Site Preparation Guidelines Electrical Factors Figure 2-1 Raised Floor Metal Strip Ground System 60SP010A 11/30/99 18 Chapter 2 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 19
Implementation Details Connect all HP equipment cabinets to the guide for installation procedures. Wiring Connections Expansion and contraction rates vary among different metals. Therefore, the integrity impedance that causes serious problems, such as erratic equipment operation. A high impedance - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 20
floor system for minimum favorable room air distribution system (underfloor distribution). • Ensure a minimum clearance of 12 inches between the top of the hp Integrity rx5670 cabinet and the ceiling to allow for return air flow and ensure that all ceiling tiles are in place. • Allow 18 inches (or - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 21
system that serves the computer room should be capable of operating 24 hours a day, 365 days a year. It should also be independent of other systems in the building. • Consider the long-term value of hp Integrity rx5670 availability, redundant air conditioning equipment or capacity. • The system - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 22
panels is then available near the cooling air intake vents of the hp Integrity rx5670 cabinets. Return air should be ducted back to the air conditioning voltage potential. ESD can cause component damage during servicing operations. Paper feed problems on high-speed printers are usually encountered in - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 23
particles in the site environment. Specifically, disk drives, tape drives, products in a separate room to eliminate paper particulate problems. • Eating or drinking-Establish a no-eating or and become airborne, possibly causing failures or operational interruptions. For over 50 years, the electronics - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 24
General Site Preparation Guidelines Environmental Elements Although this problem is relatively rare, it may be an issue within your computer room. Since metallic contamination can cause permanent or intermittent failures on your electronic equipment, - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 25
General Site Preparation Guidelines Environmental Elements • Dropped ceiling-Cover with a commercial grade of fire-resistant, acoustic rated, fiberglass ceiling tile. • Sound deadening-Cover the walls with curtains or other sound deadening material. • Removable partitions-Use foam rubber models for - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 26
must be considered for the installation or operation of an hp Integrity rx5670. Facility characteristics are: • Floor loading • Windows • Altitude effects Floor Loading The computer room floor must be able to support the total weight of the installed hp Integrity rx5670 as well as the weight of the - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 27
usually stated as load per floor panel. The load a floor panel can support (without failure) when a wheel of specified diameter and width is rolled is satisfactory for the installation of an hp Integrity rx5670. Based on specific information provided by HP, Tate Access Floors has approved its Series - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 28
Guidelines Facility Characteristics Table 2-3 Typical Raised Floor Specifications (Continued) Itema Rating Concentrated loadb 1250 computers in a room with windows. Sunlight entering a computer room may cause problems. Magnetic tape storage media is damaged if exposed to direct sunlight. Also, - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 29
and utility outlets affect servicing operations. Plan equipment layout to hp Integrity rx5670 cabinets, larger space requirements are needed to keep ambient air intake to the hp Integrity rx5670 equipment • Cabinets for cleaning materials • Maintenance area and spare parts Floor Plan Grid - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 30
General Site Preparation Guidelines Space Requirements • Equipment cable routing 30 Chapter 2 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 31
conversion factors provided in this section are intended to ease data calculation for systems that do not conform specifically to the configurations listed in this Site Preparation Guide. Listed below are the conversion factors used in this document, as well as additional conversion factors which - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 32
schedule. • 7 days before installation - Final check made with HP site preparation specialists to resolve any last minute problems NOTE Not all installations follow a schedule like the one noted above. Sometimes, an hp Integrity rx5670 is purchased through another vendor which can preclude a rigid - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 33
. If No, include comment# or date Computer room No. Area or condition Yes No 1. Is there a completed floor plan? 2. Is there adequate space for maintenance needs? Front 36 in (91.4 cm) minimum, Rear 36 in (91.4 cm) minimum are recommended clearances. 3. Is access to the site or computer - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 34
No. Area or condition Yes No 13. Are lighting levels adequate for maintenance? 14. Are there AC outlets available for servicing needs? (i.e. vacuuming) 15. Does the input voltage correspond to equipment specifications? 15A Is dual source power used? If so, identify type(s) and evaluate - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 35
purposes? 24. Is there a fire protection system in the computer room? 25. Is antistatic flooring installed? 26. Are there any equipment servicing hazards (loose ground wires, poor lighting, etc.)? Cooling No. Area or condition Yes No 27. Can cooling be maintained between 20°C and - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 36
the appropriate information in the areas provided on the form. Special instructions or recommendations should be entered on the special instructions or recommendations form. The following list gives examples of special instructions or issues: • Packaging restrictions at the facility, such as size - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 37
Figure 2-2 Delivery Survey (Part 1) General Site Preparation Guidelines Delivery Survey Chapter 2 60SP018A 12/7/99 37 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 38
General Site Preparation Guidelines Delivery Survey Figure 2-3 Delivery Survey (Part 2) 60SP019A 11/24/99 38 Chapter 2 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 39
Power Cable The female end of the power cable is a C15 type plug that mates with the receptacle in each power supply installed in the HP Server. Figure 3-1 Male Receptacle (at power supply) Figure 3-2 C15 Female Plug (on one end of the power cord) Chapter 3 39 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 40
Power Cable Male End of Power Cable The male plug on the other end of the power cable will vary depending on the region the HP Server is shipped to. Several examples follow though this list is not meant to be all inclusive. Figure 3-3 Unterminated Plug Figure 3-4 L6-20 Plug Figure 3-5 IEC - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 41
Figure 3-7 L6-30 Plug Figure 3-8 fig007 NEMA 5-20P Plug Figure 3-9 ISI 32 Plug Power Plug Configuration Male End of Power Cable Chapter 3 41 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 42
Power Plug Configuration Male End of Power Cable Figure 3-10 GB 1002 Plug 42 Chapter 3 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 43
Power Plug Configuration Power Cable Power Cable The power cable length and configuration will vary based on the region the server ships to. This is an example of one power cable configuration used to supply power to the server. Figure 3-11 L6-20 Power Cable Chapter 3 43 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 44
Power Plug Configuration Power Cable 44 Chapter 3 - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 45
of heat transfer rate. C CompactPCI The newest specification for PCI-based industrial computers is called CompactPCI. AC lines and ground. Maximum input current The operating current of the product equal to the maximum Commission) regulates a portion of this problem through Part 15 of their rules and - HP Integrity rx5670 | Site Preparation Guide - HP Integrity rx5670 (A6837B/A683 - Page 46
The PCI Industrial Computer Manufacturers Group (PICMG) controls the PICMG specification. Power factor The ratio of true power to apparent power or current of an AC wave. To determine rms value, three mathematical operations are carried out on the function representing the AC waveform: (1) The
hp Integrity rx5670
Site Preparation Guide
Product ID: A6837B/A6838B
Manufacturing Part Number : rx5670_SitePrep
July 2003
U.S.A.
© Copyright 2003,
Hewlett-Packard Development Company, L.P.