installation and user information updating software Installation Steps 1 Find out current version 2 Verify prerequisites. 3 Download software and install script 1. Verify that you have previous sv6_enhancements software on your master system. 2. If you do not have a previous version of this sv6 software and/or June 2001 or later X server and OpenGL on your system, do not install the sv6_enhancements bundle. Contact HP Support. 1. Must be able to login as root on master node, which is connected to an HP sv6 compositor. 2. Verify that /var/opt/sps/sv6files/sv6_targets contains gigabit hostnames for all systems in the configuration. (i.e. svm sv1 ...sv16) 3. Must be a rack of HPUX 11.0 workstations configured according to sv6 standards which includes these critical ones: • A recent version of the Quality Pack is highly recommended. It contains graphics patches and other standard HP patches. • Must have June 2001 or newer X server and OpenGL (PHSS_23546, PHSS_23544,5) and/or an SV6 Core Update patch installed. Check date by running: what /opt/graphics/OpenGL/lib/libGL.1 • SD tools must be configured for swinstall to multiple targets (touch /var/adm/sw/.sdkey) and allow root access from the master node to all slave nodes (swacl). • Master has root permissions assigned in /.rhosts on all slave nodes. • Gigabit network must be functional: (remsh sv1 echo hello) • See other details in the scalable visualization guides at: http://www.hp.com/workstations/support/document ation/hpux_manuals.html#scalablevis 1. Download and save the sv6_enhancements and install_sv6_enhancements files on the master system. 48 Chapter 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

installation and user information
updating software
Chapter 2
48
Installation Steps
1
Find out current version
1.
Verify that you have previous sv6_enhancements
software on your master system.
2.
If you do not have a previous version of this sv6 software
and/or June 2001 or later X server and OpenGL on your
system, do not install the sv6_enhancements bundle.
Contact HP Support.
2
Verify prerequisites.
1.
Must be able to login as root on master node, which is
connected to an HP sv6 compositor.
2.
Verify that /var/opt/sps/sv6files/sv6_targets contains
gigabit hostnames for all systems in the configuration.
(i.e. svm sv1 …sv16)
3.
Must be a rack of HPUX 11.0 workstations configured
according to sv6 standards which includes these critical
ones:
A recent version of the Quality Pack is highly
recommended. It contains graphics patches and other
standard HP patches.
Must have June 2001 or newer X server and OpenGL
(PHSS_23546, PHSS_23544,5) and/or an SV6 Core
Update patch installed. Check date by running:
what /opt/graphics/OpenGL/lib/libGL.1
SD tools must be configured for swinstall to multiple
targets (touch /var/adm/sw/.sdkey) and allow root
access from the master node to all slave nodes
(swacl).
Master has root permissions assigned in /.rhosts on
all slave nodes.
Gigabit network must be functional:
(
remsh sv1 echo hello
)
See other details in the scalable visualization guides
at:
ation/hpux_manuals.html#scalablevis
3
Download software and
install script
1.
Download and save the sv6_enhancements and
install_sv6_enhancements files on the master system.