HP Kayak XU 04xx HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring
HP Kayak XU 04xx Manual
View all HP Kayak XU 04xx manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Kayak XU 04xx manual content summary:
- HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 1
HP MaxiLife® Hardware Monitoring The described HP MaxiLife Hardware Monitoring feature is only valid for HP Kayak XU Series 0441 and XW Series 0480 PC Workstations. These PC Workstations are installed with the Intel Pentium® Xeon™ processor. 1 - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 2
errors, package intrusions), and other miscellaneous functions (such as special OK/FAIL symbols based on a smiling face). HP MaxiLife Architecture The HP MaxiLife chip continuously monitors temperature and voltage sensors located in critical regions on the system board. This chip receives data about - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 3
, an error screen appears indicating the problem. Using HP MaxiLife When the Computer Is Powered Off NOTE HP MaxiLife is powered by VSTBY. This means selected, the main power supply is started, enabling the hardware monitoring chip to access the status of the computer's components. Although - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 4
NOTE HP MaxiLife® Hardware Monitoring When the diagnostics tests are complete, one of the following screens will be displayed: Diagnostics: Done when exiting the test session. On/Off transitions are accompanied with a 'Please wait' screen to allow HP MaxiLife to power on and off correctly. 4 - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 5
HP MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages HP MaxiLife Test Sequence and Error if a fan cable is not connected). This type of error disappears dynamically when the problem has been fixed (for example, the fan cable has been reconnected). The different diagnostics - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 6
HP MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages The first detected it encounters an error. CPU or Terminator PLL Frequence Vcc State (5V) PGOOD (VRM output) HP MaxiLife Firmware Error! CPU Socket LCD Status Panel Voltage 12V Voltage CPU1, CPU2 I2C Bus DIMM - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 7
HP MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages Table 1 The following table shows the test sequence carried out, the type of error message, and the action to - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 8
video controller is correctly installed. Note: No error is detected if a monitor is not connected to an installed video controller. This is not a BIOS boot code (POST phase) from the first CPU instructions through to DIMM detection, HP MaxiLife firmware waits for a synchronization event from the BIOS - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 9
Monitoring HP MaxiLife Test Sequence and Error Messages The following diagrams show the different BIOS-generated errors. "BIOS" ERROR BIOS "read DIMM 1" HP check the list of errors available on the HP World-Wide Web support page: http://www.hp.com/go/kayaksupport Operating System Boot Phase If - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 10
HP MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages Table 3 Run-Time Errors During the normal usage of the PC, HP MaxiLife continualy checks some of the vital system parameters. These include: temperature errors, fan malfunctions, power voltage drops, board PLL problems - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 11
MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages System Info Boot Steps Obtains information from the BIOS and the system's Serial EEPROM from a previously successful boot. This information includes: product name (HP Kayak XU, or XW), BIOS version, serial number, number of - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 12
MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages Diagnostics Runs a set of diagnostics assessing the system's components. Results of the tests are displayed on the LCD status panel, one after another when the LCD buttons are pressed. For HP MaxiLife to access the status - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 13
MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages OFF Request for Super I/O NS317 chip System info Boot steps Next Go Next Diags Exit Next Go Enter Please - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 14
HP MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages Typical Diag Error Messages When will indicate a BIOS error: The BIOS no longer works. There is no Flash. HP KAYAK XU Error! CPU Socket Error! Power CPU 1 Error! CPU Socket Error! Power CPU 1 Error! Power supply - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 15
HP MaxiLife® Hardware Monitoring HP MaxiLife Test Sequence and Error Messages Table 4 The components Unbuffered and Registered memory modules. For More Information About HP MaxiLife Refer to the online Upgrade and Configuration Guide for more information about this diagnostics utility at the - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 16
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Order in Which the Tests Are Performed and initializes certain system parameters. The POST starts by displaying a graphic screen of the HP PC Workstation's logo when the PC is restarted. If you wish to view the POST details, press to - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 17
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed The following table lists the POST checkpoint codes written at the start of each test. Checkpoint Code POST - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 18
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Checkpoint Code POST Routine Description 2Ah Clear 512 KB base RAM 32h Test CPU bus-clock frequency 33h - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 19
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Checkpoint Code POST Routine Description 52h Test keyboard 54h Set key click if enabled 56h Enable keyboard 59h Initialize POST display service 5Ah Display prompt "Press F2 to enter SETUP" 5Bh Disable CPU cache - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 20
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Checkpoint Code POST Routine Description 80h Disable onboard Super I/O ports and IRQs 81h Late POST device initialization 82h - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 21
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Checkpoint Code 9Dh 9Eh 9Fh A0h A2h A4h A8h AAh ACh AEh B0h B2h B5H B6h B8h B9h - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 22
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Checkpoint Code POST Routine Description C3h Initialize error display function C4h Initialize system error handling C5h Plug and - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 23
HP MaxiLife® Hardware Monitoring Order in Which the Tests Are Performed Checkpoint Code POST Routine Description F2h Initialize video F3h Initialize system management mode F5h Boot to Mini DOS F6h Clear huge segment F7h Boot to Full DOS 1. Depending on the BIOS Setup configuration. 23 - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 24
HP MaxiLife® Hardware Monitoring Error Message Summary Error Message Summary The Error Message prompts) Category #4: if the error is serious, the POST should prompt: The BIOS has detected a serious problem that prevents your PC from booting." , and stop. Only - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 25
HP MaxiLife® Hardware Monitoring Error Message Summary The following table lists the error codes, causes and symptoms, and the accompanying short messages that are displayed in the upper left - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 26
HP MaxiLife® Hardware Monitoring Error Message Summary Code # Cause / Symptom 0310h 0311h 0305h 0306h 0307h 0400h 0401h 0500h 0501h 0510h 0511h 0512h 0513h 0520h 0521h 0522h 0523h 0530h 0531h - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 27
HP MaxiLife® Hardware Monitoring Error Message Summary Code # Cause / Symptom Short message (US) 0731h by POST. Check that your boot device is enabled on the Setup Security menu. If the problem persists, check that the boot device contains the operating system. If you have configured HDD user - HP Kayak XU 04xx | HP Kayak XU Series 04xx, HP MaxiLife Hardware Monitoring - Page 28
HP MaxiLife® Hardware Monitoring Beep Codes Beep Codes If a terminal error occurs during means data bits 12 and 5 (bits 12 and 5 set) have failed in the lower 16 bits. HP MaxiLife® is a registered trademark of Hewlett-Packard. Pentium® is a registered trademark of Intel Corporation. Xeon™ is a
1
HP MaxiLife
®
Hardware Monitoring
The described HP MaxiLife Hardware Monitoring feature is only valid for
HP Kayak XU Series 0441 and XW Series 0480 PC Workstations. These PC
Workstations are installed with the Intel Pentium
®
Xeon
™
processor.