HP LH4r HP Netserver LXr Pro NetRAID Config Guide for Windows NT4.0 Clusters - Page 2
Storage
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Hot swap cages Local storage I/O slots: Storage Local Physical drive location Disk drives Controller SCSI Bus Shared Controller Model No. of controllers Firmware Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks Configuration options: 200 MHz. 2 - 4 (at least 2 are required) 1.00.09.CDOL or later Any size 128 MB minimum. Must be HP. 3 May use for local storage; but not use for shared storage. Internal or external, using any controller. Must use HP disks. See Local Storage below. P4 - P6 Shared storage controller P3 or P4 - NetRAID local storage P2 - Intra-cluster (Heartbeat) LAN P1 - Client LAN All others - Any other plug-in cards. SPU internal drive bays, or HP external drive cabinet (e.g., HP Storage System/8) Must be HP SPU embedded controller or any controller (any number, manufacturer or driver) in any available I/O slot. Use P3 or P4 for NetRAID local storage. See SPU I/O slots above. Any HP cables that meet SCSI specifications and any SCSI bus speed HP NetRAID D4943A Use with HP Rack Storage/8 (D4902A) and HP Cluster Adapter only. 1-2 S.01.00 2.03 A.01.09 P4 - P6 6, 7 0 and 1 only Do not use channel 2 for any purpose. 1, 5, 10 and 50 only 1 per RAID array 6 maximum per NetRAID adapter Cluster mode on (cache write-through, no hot spare) Ultra SCSI disabled Termination: wide channel or automatic Set any other options as you prefer Cabinet Model No. of cabinets HP Rack Storage/8 D4902A 1-4 2