HP LH4r HP Netserver LXr Pro NetRAID Config Guide for Windows NT4.0 Clusters - Page 4

Shared Storage Cabling

Page 4 highlights

Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LXr Pro and HP Rack Storage/8s. Only these cabling configurations and cables are supported. NetRAID Ch. 0 NetRAID Ch. 1 NOTES: 1. Configure cluster using 1 or 2 Rack Storage/8s. 2. Channel 0 and 1 of each NetRAID Adapter for each Lxr Pro must be connected together through the Rack Storage/8 as shown in the diagram. Do not cross channels. 3. The NetRAID Adapter may be installed in Lxr Pro PCI slots P4-P6. (The diagram depicts using slot P4.) 4. Cables between the servers and shared storage must be D5957A Cluster Adapters. NetRAID Ch. 0 NetRAID Ch. 1 HP Microsoft Cluster Server with One NetRAID Adapter 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

4
Shared Storage Cabling
This part of the guide defines the allowable cabling configurations for clusters using the HP
NetServer LXr Pro and HP Rack Storage/8s. Only these cabling configurations and cables are
supported.
NetRAID Ch. 0
NetRAID Ch. 1
NetRAID Ch. 0
NetRAID Ch. 1
NOTES:
1.
Configure cluster using 1 or 2
Rack Storage/8s.
2.
Channel 0 and 1 of each NetRAID
Adapter for each Lxr Pro must be
connected together through the
Rack Storage/8 as shown in the
diagram.
Do not cross channels.
3.
The NetRAID Adapter may be
installed in Lxr Pro PCI slots P4-P6.
(The diagram depicts using slot P4.)
4.
Cables between the servers and
shared storage must be D5957A Cluster
Adapters.
HP Microsoft Cluster Server with One NetRAID Adapter