HP Latex R1000 Site Preparation Guide - Page 33
Checklist, Are Residual-Current Circuit Breakers RCCB, also known as Ground Fault Circuit
View all HP Latex R1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Electrical installation Has the site been prepared for the chosen power option? Configuration 1 branch circuit breaker: 4 poles, 40/50 A Configuration 2 branch circuit breaker: 3 poles, 63/70 A Configuration 3 branch circuit breaker: ● Three-phase: 4 poles, 40/50 A ● Two-phase control: 2 poles, 15/16/20 A Configuration 4 branch circuit breaker: ● Three-phase: 3 poles, 63/70 A ● Two-phase control: 2 poles, 15/16/20 A Is the chosen power system within its nominal range? Configuration 1 Configuration 2 Configuration 3 Configuration 4 Is the grounding conductor properly installed, as shown in the site preparation guide? Have you booked the services of an electrician for the day of installation? Is the electrician aware of all requirements and specifications highlighted in this document? Is the Power Distribution Unit (PDU) correctly installed? Are Residual-Current Circuit Breakers (RCCB), also known as Ground Fault Circuit Interrupters (GFCI), required by local laws? if so, have they a sensitivity of 100 mA or higher? Yes No Electrical configuration Yes No Do you need an Uninterrupted Power Supply (UPS)? If so, is it correctly installed? No power cords are supplied with the printer; does the electrician understand that power cord(s) must be provided according to printer specifications and local laws? If local regulations specify that you must use electrical plugs to connect the printer to the power supply, does the electrician have the required plugs ready for installation? Networking requirements Have network connections been supplied? Do you have a LAN cable long enough to connect the printer to the network? Do you have an Internet connection? Yes No Comments (Required) (Required) (Required) (Required) (Required) (Required) Comments Comments ENWW Checklist 29