HP NetServer AA 6200 Backup/Recovery Guide for HP AA Solutions - Page 9

Marathon MTCETHR Virtual Adapter private backup LAN on CE

Page 9 highlights

Disable - NetBEUI Protocol Enable - TCP/IP Protocol Enable - Wins Client (TCP/IP) Enable - Marathon Datagram Services Enable - Marathon Ethernet Provider Disable - MTCEtx driver New Network Adapter (for dedicated backup CE network) Disable - NetBEUI Protocol Disable - TCP/IP Protocol Disable - Wins Client (TCP/IP) Enable - Marathon Datagram Services Enable - Marathon Ethernet Provider Disable - MTCEtx driver After completing the adapter bindings, then configure a unique IP address for each dedicated IOP NIC. For dedicated backup CE NIC (one in each IOP because mirrored for AA), use the Marathon manager in IOP1 and IOP2 to configure a second NIC into the CE. Next, go into CE network properties and add an additional Marathon MTCETHR Virtual Adapter. Set up the adapter bindings as follows. Marathon MtcVnR (for internal communication between IOP1 and CE) Enable - NetBEUI Protocol Disable - TCP/IP Protocol Disable - Wins Client (TCP/IP) Marathon MtcVnR (for internal communication between IOP2 and CE) Enable - NetBEUI Protocol Disable - TCP/IP Protocol Disable - Wins Client (TCP/IP) Marathon MTCETHR Virtual Adapter (public LAN on CE) Enable - NetBEUI Protocol Enable - TCP/IP Protocol Enable - Wins Client (TCP/IP) Marathon MTCETHR Virtual Adapter (private backup LAN on CE) Enable - NetBEUI Protocol Enable - TCP/IP Protocol Enable - Wins Client (TCP/IP) Set up a separate IP address (different than the original CE user IP) for the dedicated backup network. The dedicated backup network with IOP1, IOP2, CE1 and CE2 backup 12/08/99 Hewlett-Packard Co. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

12/08/99
Hewlett-Packard Co.
9
Disable - NetBEUI Protocol
Enable - TCP/IP Protocol
Enable - Wins Client (TCP/IP)
Enable - Marathon Datagram Services
Enable - Marathon Ethernet Provider
Disable - MTCEtx driver
New Network Adapter (for dedicated backup CE network)
Disable - NetBEUI Protocol
Disable - TCP/IP Protocol
Disable - Wins Client (TCP/IP)
Enable - Marathon Datagram Services
Enable - Marathon Ethernet Provider
Disable - MTCEtx driver
After completing the adapter bindings, then configure a unique IP address for each
dedicated IOP NIC.
For dedicated backup CE NIC (one in each IOP because mirrored for AA), use the
Marathon manager in IOP1 and IOP2 to configure a second NIC into the CE.
Next, go into CE network properties and add an additional Marathon MTCETHR Virtual
Adapter. Set up the adapter bindings as follows.
Marathon MtcVnR (for internal communication between IOP1 and CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
Marathon MtcVnR (for internal communication between IOP2 and CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
Marathon MTCETHR Virtual Adapter (public LAN on CE)
Enable – NetBEUI Protocol
Enable – TCP/IP Protocol
Enable – Wins Client (TCP/IP)
Marathon MTCETHR Virtual Adapter (private backup LAN on CE)
Enable – NetBEUI Protocol
Enable – TCP/IP Protocol
Enable – Wins Client (TCP/IP)
Set up a separate IP address (different than the original CE user IP) for the dedicated
backup network.
The dedicated backup network with IOP1, IOP2, CE1 and CE2 backup