HP NetServer LXr Pro8 HP Netserver LPr NetRAID-4M Config Guide for Windows 20
HP NetServer LXr Pro8 Manual
View all HP NetServer LXr Pro8 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP NetServer LXr Pro8 manual content summary:
- HP NetServer LXr Pro8 | HP Netserver LPr NetRAID-4M Config Guide for Windows 20 - Page 1
HP NetServer LPr with NetRAID-4M (HP Rack Storage/12) Windows® 2000 Advanced Server Cluster Configuration Guide 27 March 2001 (see Versions at the end of this document) Introduction This document defines the configurations that Hewlett-Packard supports for the HP NetServer LPr, HP Rack Storage/12 - HP NetServer LXr Pro8 | HP Netserver LPr NetRAID-4M Config Guide for Windows 20 - Page 2
20.00 or later. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any Shared Controller Model No. of controllers BIOS Firmware Driver NetRAID-4M FAST HP NetRAID-4M Adapter D9161A or D9351A - HP NetServer LXr Pro8 | HP Netserver LPr NetRAID-4M Config Guide for Windows 20 - Page 3
drives: No. of cabinets Model Status SCSI ID Disk SCSI Ids Cables LANs LAN connection NIC: Model Driver No. of NICs 6, 7 0, 1, 2, 3 All fault tolerant RAID types supported Enabled Domain Validation Enabled Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in - HP NetServer LXr Pro8 | HP Netserver LPr NetRAID-4M Config Guide for Windows 20 - Page 4
connecting local storage drives. 3. Cables between the servers and shared storage cabinets must be HP LVD SCSI (offset) of any length up to 10 meters. See "Cables"in Rack Storage/12 of the guide for a list of cables by part number that can be used. HP NetServer LPr Cluster using HP Rack Storage/12 - HP NetServer LXr Pro8 | HP Netserver LPr NetRAID-4M Config Guide for Windows 20 - Page 5
Power Cabling to Separate Power Circuits 5 - HP NetServer LXr Pro8 | HP Netserver LPr NetRAID-4M Config Guide for Windows 20 - Page 6
Versions 27 March 2001 14 March 2001 Corrected NetRAID-1M/2M driver name and version. Initial release © Copyright 2001, Hewlett-Packard Company 6
1
HP NetServer LPr
with
NetRAID-4M (HP Rack Storage/12)
Windows
2000 Advanced Server
Cluster Configuration Guide
27 March 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configurations that Hewlett-Packard supports for the HP NetServer LPr, HP
Rack Storage/12 and Microsoft
Cluster Server.
These configurations minimize single points of failure
(SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft
is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LPr
Each node must be the same SPU, but may have different clocks speeds,
main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-4M controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft
approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable or equivalent. See
Intra-cluster LAN
below.