Storage

Page 2 highlights

Power source System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots Default Boot Order Microsoft® and HP Certified Configuration Storage Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.20.00 or later Microsoft Windows® 2000 Advanced Server SP1 HP NetServer LPr 850 MHz 2 - 6 4.06.35 PR or later Any size 256 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4 P1 - Shared Storage - NetRAID-4M P2 - Client LAN - D5013B P3 - Local Storage - NetRAID-1Si P4 - Intra-cluster (Heartbeat) LAN Booted from NetRAID-1Si Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or NetRAID-2M. For embedded SCSI, use sym_hi.sys 4.12 or later. For NetRAID-xSi, use mraid35x.sys version 2.66. For NetRAID-1M/2M, use mraid2k.sys, version 5.20 or later. All are from Navigator L.20.00 or later. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any Shared Controller Model No. of controllers BIOS Firmware Driver NetRAID-4M FAST HP NetRAID-4M Adapter D9161A or D9351A 2 Disabled 4584 Hpn.sys version 2.4.0.4581 2.4-0 or later 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.20.00 or later
Operating System
Service Pack
Microsoft Windows
2000 Advanced Server
SP1
SPU
Model
HP NetServer LPr
Clock speed
850 MHz
No. of CPUs
2 - 6
BIOS version
4.06.35 PR or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
Microsoft
and HP
Certified
Configuration
P1 – Shared Storage – NetRAID-4M
P2 – Client LAN – D5013B
P3 – Local Storage – NetRAID-1Si
P4 – Intra-cluster (Heartbeat) LAN
Booted from NetRAID-1Si
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or
NetRAID-2M.
Driver
For embedded SCSI, use sym_hi.sys 4.12 or later.
For NetRAID-xSi, use mraid35x.sys version 2.66
.
For NetRAID-1M/2M, use mraid2k.sys, version 5.20 or later.
All are from Navigator L.20.00 or later.
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-4M Adapter D9161A or D9351A
No. of controllers
2
BIOS
Disabled
Firmware
4584
Driver
Hpn.sys version 2.4.0.4581
NetRAID-4M FAST