NetRAID-4M Channels 1 3 0 2 All channels are for shared storage use only. LEGEND Color coding depicts that NetRAID channels must not be crossed as they connect from one NetServer to the other through the shared storage device. Any channels (0-3) can be used. NOTES: 1. This diagram depicts using 3 Rack Storage/12s. Up to 4 RS/12 storage cabinets may be used per NetRAID-4M (up to 2). 2. The NetRAID4M Adapter is depicted in server PCI slot P1. A NetRAID-xSi or xMmay also be installed for connecting local storage drives. 3. Cables between the servers and shared storage cabinets must be HP LVD SCSI (offset) of any length up to 10 meters. See "Cables"in Rack Storage/12 of the guide for a list of cables by part number that can be used. HP NetServer LPr Cluster using HP Rack Storage/12 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

4
HP NetServer LPr Cluster using HP Rack Storage/12
NOTES:
2.
The NetRAID4M Adapter is
depicted in server PCI slot P1.
A NetRAID-xSi or xMmay also be installed
for connecting local storage drives.
3.
Cables between the servers and
shared storage cabinets must be HP
LVD SCSI
(offset) of any length up to
10 meters.
See “Cables”in Rack
Storage/12 of the guide for a list of
cables by part number that can be used.
1.
This diagram depicts using 3
Rack Storage/12s. Up to 4 RS/12 storage
cabinets may be used per NetRAID-4M
(up
to 2).
LEGEND
Color coding depicts that NetRAID
channels must not be crossed as
they connect from one NetServer
to the other through the shared
storage device.
Any channels (0-3)
can be used.
NetRAID-4M Channels
All channels are for shared
storage use only.
0
1
3
2