Small Form Factor Table D-3 Specifications - HP Pro 3000/3080 Small Form Factor Desktop Dimensions Height 3.98 in 101 mm Width 13.35 in 339 mm Depth 15.24 in 387 mm Approximate Weight 14.95 lb 6.81 kg Temperature Range Operating 50° to 95°F 10° to 35°C Nonoperating -22° to 140°F -30° to 60°C Relative Humidity (noncondensing) Operating 10-90% 10-90% Nonoperating (38.7°C max wet bulb) 5-95% 5-95% Maximum Altitude (unpressurized) Operating 10,000 ft 3048 m Nonoperating 30,000 ft 9144 m NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Heat Dissipation For 115V/60Mhz For 230V/50Hz Maximum Typical (idle) 250W PFC HV TFX: 250W PFC HV TFX: 173.9W or 593.35 BTU/ hr 250W PFC TFX: 179.2W or 611.43 BTU/ hr 172.3W or 587.89 BTU/hr 250W PFC TFX: 174.8W or 596.42 BTU/hr For 115V/60Mhz For 230V/50Hz 250W PFC HV TFX: 250W PFC HV TFX: 51.9W or 177.0828 BTU/ 51.4W or 175.3768 hr BTU/hr 250W PFC TFX: 250W PFC TFX: Power Supply 52.8W or 180.1536 BTU/ 53.3W or 181.8596 hr BTU/hr 115V 230V Operating Voltage Range Rated Voltage Range 90-132 VAC 100-127 VAC 180-264 VAC 200-240 VAC Rated Line Frequency 50-60 Hz 50-60 Hz 180 Appendix D Specifications