HP Pro 3080 Maintenance & Service Guide: HP Pro 3000/3010/3080 Business PC - Page 191

Specifications - HP Pro 3010 Small Form Factor, Table D-4

Page 191 highlights

Table D-3 Specifications - HP Pro 3000/3080 Small Form Factor (continued) Power Output 300 W 300 W Rated Input Current (maximum)1 8A @ 100 VAC 4A @ 200 VAC 1 This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European Union. This supply requires the use of an input voltage range select switch. Table D-4 Specifications - HP Pro 3010 Small Form Factor Desktop Dimensions Height 3.98 in 101 mm Width 13.35 in 339 mm Depth 15.24 in 387 mm Approximate Weight 14.95 lb 6.78 kg Temperature Range Operating 50° to 95°F 10° to 35°C Nonoperating -22° to 140°F -30° to 60°C Relative Humidity (noncondensing) Operating 10-90% 10-90% Nonoperating (38.7°C max wet bulb) 5-95% 5-95% Maximum Altitude (unpressurized) Operating 10,000 ft 3048 m Nonoperating 30,000 ft 9144 m NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Heat Dissipation Maximum 1575 BTU/hr 397 kg-cal/hr Typical (idle) 307 BTU/hr 77 kg-cal/hr Power Supply 115V 230V Operating Voltage Range 90-132 VAC 180-264 VAC Rated Voltage Range 100-127 VAC 200-240 VAC Rated Line Frequency 50-60 Hz 50-60 Hz Power Output 300 W 300 W Rated Input Current (maximum)1 8A @ 100 VAC 4A @ 200 VAC 1 This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European Union. This supply requires the use of an input voltage range select switch. Small Form Factor 181

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

Power Output
300 W
300 W
Rated Input Current (maximum)
1
8A @ 100 VAC
4A @ 200 VAC
1
This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V
operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European
Union. This supply requires the use of an input voltage range select switch.
Table D-4
Specifications – HP Pro 3010 Small Form Factor
Desktop Dimensions
Height
Width
Depth
3.98 in
13.35 in
15.24 in
101 mm
339 mm
387 mm
Approximate Weight
14.95 lb
6.78 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no
direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and
number of options installed.
Heat Dissipation
Maximum
Typical (idle)
1575 BTU/hr
307 BTU/hr
397 kg-cal/hr
77 kg-cal/hr
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
115V
90-132 VAC
100-127 VAC
50-60 Hz
230V
180-264 VAC
200-240 VAC
50-60 Hz
Power Output
300 W
300 W
Rated Input Current (maximum)
1
8A @ 100 VAC
4A @ 200 VAC
1
This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V
operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European
Union. This supply requires the use of an input voltage range select switch.
Table D-3
Specifications – HP Pro 3000/3080 Small Form Factor (continued)
Small Form Factor
181