HP ProLiant 2500 Compaq ProLiant Cluster HA/F100 and HA/F200 Administrator Gui - Page 130
Troubleshooting Node-to-Node Problems, Table 6-2
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Troubleshooting the Compaq ProLiant Clusters HA/F100 and HA/F200 6-5 Troubleshooting Node-to-Node Problems This section describes problems that may be encountered during server-to-server communication. Table 6-2 Solving Node-to-Node Problems Problem The resources failed over but the nodes do not see each other. Node failover is not recognized by Redundancy Manager. Possible Cause No connectivity between the nodes. Cluster may be improperly cabled. Action 1. Run Control Panel service applet on both nodes and verify the RPC service is running. 2. Use a network analyzer (such as Network Monitor), or RPCPing (available on the Microsoft Exchange Server CD) to ensure RPC connectivity exists on both nodes. Refer to the Compaq ProLiant Cluster HA/F200 Installation Poster for proper cabling of the cluster. continued