HP ProLiant DL360e HP Smart Update Manager 5.1 Release Notes - Page 4

Enhancements, Fixes, Prerequisites, on the HP Smart Update Manager Information Library

Page 4 highlights

Enhancements • New Hardware Support ◦ CPLD firmware ◦ Support for 6Gb SAS BL switches • Failed dependency report A new Failed Dependency report is now available when you generate other reports. • New report format The report format has been changed. You can view all reports from one HTML file. Fixes The following known issues have been resolved in this version of HP SUM: • The Install Options and Feedback screens have not been localized in Japanese. • HP SUM for Windows version 5.0.0 in Japanese will show corrupted names for NICs in the generated firmware report. • Report Generation with CLI is not correct. • The top three buttons are not available if a target with no applicable components is selected. • HP SUM might show the installed version of P2000/MSA2000 components as NULL. • Broadcom NIC components might show the status as Ready for installation after restarting HP SUM. • The component HP Intel Online Firmware Upgrade Utility Linux x86 and x86_64 is unable to re-install via the force install option offline if it is already up to date. • After an update using the HP SUM and the PSP 9.00 for Windows, the IML log viewer might show No system management driver is loaded, although it is installed. • HP SUM might list VB0250EAVER Drives as Updates to be installed and show the installed version as HPG0 and the available version as HPG7, but will not update the firmware. For more information about the fixes, see the HP Smart Update Manager Release Notes 5.0.1, available on the HP Smart Update Manager Information Library at http://www.hp.com/go/hpsum/ documentation. Prerequisites IMPORTANT: Before deploying any components to a system, be sure that a recent backup of the system is available in the event the deployment procedure fails. Windows The minimum requirements when running HP SUM or deploying components to systems running a Microsoft Windows operating system include the following: • A local administrative system with 1 GB of memory • Sufficient hard-drive space of at least twice the file size of the components to be deployed • WMI enabled • All remote targets must be visible by the administrative system running HP SUM • An account with administrator privileges on each target server 4 Enhancements

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

Enhancements
New Hardware Support
CPLD firmware
Support for 6Gb SAS BL switches
Failed dependency report
A new Failed Dependency report is now available when you generate other reports.
New report format
The report format has been changed. You can view all reports from one HTML file.
Fixes
The following known issues have been resolved in this version of HP SUM:
The Install Options and Feedback screens have not been localized in Japanese.
HP SUM for Windows version 5.0.0 in Japanese will show corrupted names for NICs in the
generated firmware report.
Report Generation with CLI is not correct.
The top three buttons are not available if a target with no applicable components is selected.
HP SUM might show the installed version of P2000/MSA2000 components as NULL.
Broadcom NIC components might show the status as
Ready for installation
after restarting
HP SUM.
The component
HP Intel Online Firmware Upgrade Utility Linux x86 and
x86_64
is unable to re-install via the force install option offline if it is already up to date.
After an update using the HP SUM and the PSP 9.00 for Windows, the IML log viewer might
show
No system management driver is loaded
, although it is installed.
HP SUM might list VB0250EAVER Drives as
Updates to be installed
and show the installed
version as
HPG0
and the available version as
HPG7
, but will not update the firmware.
For more information about the fixes, see the HP Smart Update Manager Release Notes 5.0.1, available
on the HP Smart Update Manager Information Library at
h
t
tp://w
w
w
.hp
.co
m/go/hp
sum/
doc
ume
n
t
ati
o
n
.
Prerequisites
IMPORTANT:
Before deploying any components to a system, be sure that a recent backup of the
system is available in the event the deployment procedure fails.
Windows
The minimum requirements when running HP SUM or deploying components to systems running a
Microsoft Windows operating system include the following:
A local administrative system with 1 GB of memory
Sufficient hard-drive space of at least twice the file size of the components to be deployed
WMI enabled
All remote targets must be visible by the administrative system running HP SUM
An account with administrator privileges on each target server