HP ProLiant DL380 Smart Array 5i Plus Controller and Battery Backed Write Cach - Page 112

System Configuration Utility if a SMART-2/E is not, SMART-2/E 8-bit

Page 112 highlights

POST Error Messages Table F-1: POST Error Messages continued Message Description Meaning and Recommended Action 1764 Slot x drive array - capacity expansion process is temporarily disabled (followed by a cause). The capacity expansion process has been temporarily disabled for the reason indicated and will automatically resume. If the array accelerator has been removed, you must reinstall it for capacity expansion to continue. 1765 Slot x drive array Option ROM appears to conflict with an ISA card - ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with SMART-2/E 8-bit Option ROM due to EISA buffer limitations. Please remove or reconfigure your ISA card. Remove or reconfigure the conflicting ISA card, referring to the directions provided with the ISA card. Alternatively, the Option ROM can be disabled on the SMART-2/E controller through the System Configuration Utility if a SMART-2/E is not the primary (boot) controller. 1766 Slot x drive array requires System ROM upgrade. Run the latest version of the System ROMPaq utility. Run System ROMPaq Utility. continued F-6 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

POST Error Messages
F-6
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
Table F-1:
POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1764
Slot x drive array
capacity expansion
process is temporarily
disabled (followed by a
cause).
The capacity expansion process has been
temporarily disabled for the reason indicated and
will automatically resume. If the array accelerator
has been removed, you must reinstall it for
capacity expansion to continue.
1765
Slot x drive array
Option ROM appears
to conflict with an ISA
card
ISA cards with
16-bit memory cannot
be configured in
memory range C0000
to DFFFF along with
SMART-2/E 8-bit
Option ROM due to
EISA buffer limitations.
Please remove or
reconfigure your ISA
card.
Remove or reconfigure the conflicting ISA card,
referring to the directions provided with the ISA
card. Alternatively, the Option ROM can be
disabled on the SMART-2/E controller through the
System Configuration Utility if a SMART-2/E is not
the primary (boot) controller.
1766
Slot x drive array
requires System ROM
upgrade.
Run System ROMPaq
Utility.
Run the latest version of the System ROMPaq
utility.
continued