HP ProLiant DL380 Smart Array 5i Plus Controller and Battery Backed Write Cach - Page 112
System Configuration Utility if a SMART-2/E is not, SMART-2/E 8-bit
View all HP ProLiant DL380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
POST Error Messages Table F-1: POST Error Messages continued Message Description Meaning and Recommended Action 1764 Slot x drive array - capacity expansion process is temporarily disabled (followed by a cause). The capacity expansion process has been temporarily disabled for the reason indicated and will automatically resume. If the array accelerator has been removed, you must reinstall it for capacity expansion to continue. 1765 Slot x drive array Option ROM appears to conflict with an ISA card - ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with SMART-2/E 8-bit Option ROM due to EISA buffer limitations. Please remove or reconfigure your ISA card. Remove or reconfigure the conflicting ISA card, referring to the directions provided with the ISA card. Alternatively, the Option ROM can be disabled on the SMART-2/E controller through the System Configuration Utility if a SMART-2/E is not the primary (boot) controller. 1766 Slot x drive array requires System ROM upgrade. Run the latest version of the System ROMPaq utility. Run System ROMPaq Utility. continued F-6 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide