HP ProLiant SL4545 HP Scripting Toolkit 9.30 for Windows User Guide - Page 43

Controller does not support RAID Array ID., Invalid RAID.

Page 43 highlights

Error code Error message Comment or clarification 2831 Cannot change array spare. This error message appears if you try to change the number of spares in an array when the configuration does not support the addition or subtraction of spares. 2832 Invalid physical drive. A specified physical drive is not a valid physical drive, or it cannot be placed in the array. 2833 Invalid spare. A specified spare is not a valid spare drive, or it cannot be placed in the array as a spare. 2834 Invalid logical drive. - 2835 Logical drive not specified. The script file has commands that require a logical drive, but no logical drive is specified. 2836 New logical drive ID does not match the next available logical drive ID. The script file specifies a logical drive ID that is not the first unused ID in the sequence. For example, this message appears if the controller has only logical drive 1 and the script file specifies creation of logical drive 3 (omitting logical drive 2). A common cause of this error is that the input file specifies non-sequential logical drive numbers. In this case, change the logical drive numbers in the input file so that they are sequential. 2837 New logical drive ID already exists. This error occurs in Configure mode when the logical drive ID specified in the script file already exists in the configuration. In Configure mode, you can create only new logical drives. 2838 Cannot create logical drive. The array has no free space, or the maximum number of logical drives has already been reached. 2839 Cannot migrate logical drive RAID. The controller does not support RAID migration, or migration is not possible with the current controller configuration. 2840 Cannot migrate logical drive stripe size. The controller does not support stripe size migration, or migration is not possible with the current controller configuration. 2841 Cannot extend logical drive. The controller does not support extension, or the current controller configuration cannot be extended. For example, extension is not possible if the array has no free space. 2842 Invalid RAID. The specified RAID level is invalid or is not possible with the current configuration. 2843 Invalid size. The specified size is invalid or is not possible with the current configuration. 2844 Invalid stripe size. The specified stripe size is invalid, or not supported by the current RAID level, or not possible with the current configuration. 2845 Invalid sectors. The specified MaxBoot setting is invalid or is not possible with the current configuration. 2846 Cannot change logical drive sectors. You cannot change the MaxBoot setting on a configured logical drive because doing so causes data loss. 2847 Invalid array accelerator setting. The specified array accelerator setting is invalid or is not supported by the current configuration. 2848 Cannot change logical drive array accelerator setting. You cannot change the array accelerator setting for the current controller configuration. 2849 Invalid ClearConfigurationWithDataLoss - parameter. 2850 Controller does not support RAID Array ID. - Using HPACUSCRIPTING 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Comment or clarification
Error message
Error code
This error message appears if you try to change the number
of spares in an array when the configuration does not support
the addition or subtraction of spares.
Cannot change array spare.
2831
A specified physical drive is not a valid physical drive, or it
cannot be placed in the array.
Invalid physical drive.
2832
A specified spare is not a valid spare drive, or it cannot be
placed in the array as a spare.
Invalid spare.
2833
Invalid logical drive.
2834
The script file has commands that require a logical drive, but
no logical drive is specified.
Logical drive not specified.
2835
The script file specifies a logical drive ID that is not the first
unused ID in the sequence. For example, this message
New logical drive ID does not match the
next available logical drive ID.
2836
appears if the controller has only logical drive 1 and the
script file specifies creation of logical drive 3 (omitting logical
drive 2). A common cause of this error is that the input file
specifies non-sequential logical drive numbers. In this case,
change the logical drive numbers in the input file so that they
are sequential.
This error occurs in Configure mode when the logical drive
ID specified in the script file already exists in the
New logical drive ID already exists.
2837
configuration. In Configure mode, you can create only new
logical drives.
The array has no free space, or the maximum number of
logical drives has already been reached.
Cannot create logical drive.
2838
The controller does not support RAID migration, or migration
is not possible with the current controller configuration.
Cannot migrate logical drive RAID.
2839
The controller does not support stripe size migration, or
migration is not possible with the current controller
configuration.
Cannot migrate logical drive stripe size.
2840
The controller does not support extension, or the current
controller configuration cannot be extended. For example,
extension is not possible if the array has no free space.
Cannot extend logical drive.
2841
The specified RAID level is invalid or is not possible with the
current configuration.
Invalid RAID.
2842
The specified size is invalid or is not possible with the current
configuration.
Invalid size.
2843
The specified stripe size is invalid, or not supported by the
current RAID level, or not possible with the current
configuration.
Invalid stripe size.
2844
The specified MaxBoot setting is invalid or is not possible
with the current configuration.
Invalid sectors.
2845
You cannot change the MaxBoot setting on a configured
logical drive because doing so causes data loss.
Cannot change logical drive sectors.
2846
The specified array accelerator setting is invalid or is not
supported by the current configuration.
Invalid array accelerator setting.
2847
You cannot change the array accelerator setting for the
current controller configuration.
Cannot change logical drive array
accelerator setting.
2848
Invalid ClearConfigurationWithDataLoss
parameter.
2849
Controller does not support RAID Array ID.
2850
Using HPACUSCRIPTING