HP Scitex FB10000 Geffen TS Error 66115 - Page 1

HP Scitex FB10000 Manual

Page 1 highlights

Error ID: 66115: Unified Cooler - Small heater SSR fault FB10000 Error Messages Troubleshooting Error ID: 66115: Unified Cooler - Small heater SSR fault Error Severity: Error Possible Causes • Small heater CB is down • Small heater short-circuit • Ethernet line connection problem • Faulty C_H3 contactor • Faulty SSR_H1 • Faulty BM_1 B&R module • Faulty OPC Recommended Actions 1. Open the circuit breaker flap cover in the cooler front. Cooler electric panel flap FB10000 Error Messages Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5

Error ID: 66115: Unified Cooler - Small heater SSR fault
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 66115: Unified Cooler - Small heater SSR fault
Error Severity: Error
Possible Causes
Small heater CB is down
Small heater short-circuit
Ethernet line connection problem
Faulty C_H3 contactor
Faulty SSR_H1
Faulty BM_1 B&R module
Faulty OPC
Recommended Actions
1.
Open the circuit breaker flap cover in the cooler front.
Cooler electric panel flap