HP Scitex FB10000 Geffen TS Error 66115 - Page 4
while your colleague monitors the OPC status., If when you restart the cooler, the OPC Lights in green
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Error ID: 66115: Unified Cooler - Small heater SSR fault FB10000 Error Messages Troubleshooting 12. Repeat steps 7 and 8 while your colleague reports about the B&R BM_1 LED and the SSR signal (LED 5) status. 13. If when you restart the Cooler, LED 5 lights green, this indicates one of three: faulty SSR, SSR wire disconnection or faulty OPC. 14. Restart the cooler using the Service Tools SW and repeat steps 7 and 8 while your colleague monitors the OPC status. OPC in unified cooler electric panel 15. If when you restart the cooler, the OPC Lights in green, then the SSR is faulty or one of its wires disconnected. If the OPC LED does not light in green, then the problem is in the OPC and you should replace it. 16. Use a Fluke tester to measure the resistance between TB_DIS 1-2, TB_DIS 3-4 and TB_DIS 5-6. The resistance should be 88.8 - 103.5 Ω TB_DIS in Unified cooler Electric panel 4