Error ID: 66115: Unified Cooler - Small heater SSR fault FB10000 Error Messages Troubleshooting 17. While cooler is on, use an Ammeter to measure the current in TB_DIS 1-6 upper connections. If the measured current is not within the certified range (TBD), then there are three possible actions to undertake : • Current 0 means disconnection - detect the disconnected wire and connect it firmly • Current above range means short circuit in the heater - replace the small heater • Current below range means faulty large heater element - replace the small heater 18. If all these steps did not solve the problem, contact your HP regional specialist. 5

  • 1
  • 2
  • 3
  • 4
  • 5

Error ID: 66115: Unified Cooler - Small heater SSR fault
FB10000 Error Messages Troubleshooting
5
17.
While cooler is on, use an Ammeter to measure the current in TB_DIS 1-6 upper connections.
If the measured current is not within the certified range (TBD), then there are three possible actions to undertake :
Current 0 means disconnection – detect the disconnected wire and connect it firmly
Current above range means short circuit in the heater – replace the small heater
Current below range means faulty large heater element – replace the small heater