Error ID: 66032: IDS - Critical ink level in the Light Cyan main tank Troubleshooting Flowchart FB10000 Error Messages Troubleshooting LC main ink tank floater is stuck or faulty No Error ID: 66007: IDS - Critical ink level in the Light Cyan main tank LC main ink pump is faulty No Are the inputs in the In Control Tools is the In Control Tools - is the Are the outputs in the Top DI9371 B&R module Yes minimum LC main tank Yes LC feeding main tank No MM4331 B&R module Off? floater grayed? pump activated? Off? Flowchart Yes Disconnected or damaged J4 cable/ B&R module NO LC ink container Moby is clogged Yes Disconnected or damaged J5 cable/ B&R module 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 66032: IDS - Critical ink level in the Light Cyan main tank
FB10000 Error Messages Troubleshooting
Troubleshooting Flowchart
Error ID: 66007: IDS - Critical
ink level in the Light Cyan main
tank
No
Disconnected or
damaged J5 cable/
B&R module
NO
In Control Tools - is the
LC feeding
main tank
pump activated?
Yes
Yes
Are the outputs in the
MM4331 B&R module
Off?
Yes
No
Are the inputs in the
DI9371 B&R module
Off?
Yes
Disconnected or
damaged J4 cable/
B&R module
No
LC ink container
Moby is clogged
In Control Tools is the
minimum LC main tank
floater grayed?
LC main ink pump is faulty