Error ID: 66124: Unified Cooler - Temperature in coolant tank is too high (over 60º C) Air filter is clogged 1. Remove the two Air Filters out of their compartment. FB10000 Error Message Troubleshooting 2. Clean the two air filters and slide them back into their compartment. 3. Bi-Metal sensors are faulty 4. Check the three Bi-metal sensors protecting the system from overheating - SW 4-5-6. 5. If the problem persists, check the fan itself. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 66124:
Unified Cooler - Temperature in coolant tank is too high (over 60ยบ C)
FB10000 Error Message Troubleshooting
Air filter is clogged
1.
Remove the two Air Filters out of their compartment.
2.
Clean the two air filters and slide them back into their compartment.
3.
Bi-Metal sensors are faulty
4.
Check the three Bi-metal sensors protecting the system from overheating - SW 4-5-6.
5.
If the problem persists, check the fan itself.
3