HP Scitex FB10000 Geffen TS Error 66124 - Page 4

Fan is faulty

Page 4 highlights

Error ID: 66124: Unified Cooler - Temperature in coolant tank is too high (over 60º C) Fan is faulty 1. Visually inspect the cooler fan. FB10000 Error Message Troubleshooting 2. Verify that its propeller runs continuously or intermittently during operation [both cases are OK]. 3. Ensure that none of the propeller wings is bent or damaged. 4. If any of the propeller wing is damaged, replace the fan [Call HP Service] 5. If the fan does not work at all, check the fan CB. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 66124:
Unified Cooler - Temperature in coolant tank is too high (over 60ยบ C)
FB10000 Error Message Troubleshooting
Fan is faulty
1.
Visually inspect the cooler fan.
2.
Verify that its propeller runs continuously or intermittently during operation [both cases are OK].
3.
Ensure that none of the propeller wings is bent or damaged.
4.
If any of the propeller wing is damaged, replace the fan [Call HP Service]
5.
If the fan does not work at all, check the fan CB.
4