HP Scitex FB10000 Geffen TS Error 66124 - Page 7
Small Heater/SSR is faulty, Large Heater/contactor is faulty, Coolant flow fault error, Faulty
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Error ID: 66124: Unified Cooler - Temperature in coolant tank is too high (over 60º C) FB10000 Error Message Troubleshooting 14. If all LEDS in the BM_3 module are lit in red, this indicates a communication problem. 15. If only BM_3 is lit in red, this indicates that the BM_3 module caused the error and it might be faulty. 16. Replace the BM_3 B&R control module [HP Service only] 17. If the problem persists, replace the fan (HP Service] WARNING! High Voltage System! Do not touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. 18. If all these steps did not solve the problem, contact your HP Specialist. Small Heater/SSR is faulty • See error message troubleshooting # 66114. Large Heater/contactor is faulty • See error message troubleshooting # 66115. Coolant flow fault error • See error message troubleshooting # 66116 and # 66125. Faulty Temperature sensors (short circuit) • See error message troubleshooting # 66119, 66120, 66121, 66122 7