HP Scitex FB500 HP Scitex FB500 and FB700 Printer Series - User Cleaning Instr - Page 11
Re-install the lamp housings
View all HP Scitex FB500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
3. Install the spring-loaded clamp's dowels (A and B below) into the reflector. Figure 9 Installing the dowels into the reflector 4. Repeat this procedure for the other lamp. Re-install the lamp housings Re-install the user-end lamp housing 1. Secure the lamp housing to the lamp assembly using the original two lower silver screws on the user end of the carriage (see screws A in Figure 3 User end screws on page 5 for locations). ● If you have difficultly fitting the lamp housing back onto the lamp base, loosen the four screws indicated below. ● If the lamp housing is still difficult to install, squeeze the side of the lamp base to bend the side in about 0.8 mm (0.031 in). Figure 10 Loosening screws to ease installation ENWW Replace UV lamp bulb (500-1000 hours) 9