HP StorageWorks 1510i HP StorageWorks 1510i Modular Smart Array firmware 2.0 r - Page 7

Determining installed version, ARRAY, CONTROLLER FIRMWARE VER <version&gt, SHOW VERSION - storageworks msa1510i

Page 7 highlights

4. In the SMU, select Storage System > Reset System to restart the MSA1510i. IMPORTANT: In dual controller configurations, the second controller MUST be updated to the same image to complete the update cycle. When the system is restarted, the new firmware will automatically be cloned from the just-updated controller over to the other controller. For more information, see the "Redundant-controller firmware cloning" instructions in the HP StorageWorks 1510i Modular Smart Array maintenance and service guide. Determining installed version To determine the firmware installed on an MSA1510i controller, do one of the following: • On the MSA controller LCD panel, press the ^ v keys to scroll through the messages until the ARRAY CONTROLLER FIRMWARE VER message is displayed. • In the MSA-CLI, use the SHOW VERSION command. • In the Storage Management Utility (SMU) , select View MSA1510i Controller. HP StorageWorks 1510i Modular Smart Array firmware 2.0 release notes 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

4.
In the SMU, select
Storage System > Reset System
to restart the MSA1510i.
IMPORTANT:
In dual controller con
gurations, the second controller MUST be updated to the same
image to complete the update cycle. When the system is restarted, the new
rmware will
automatically be cloned from the just-updated controller over to the other controller. For
more information, see the "Redundant-controller
rmware cloning" instructions in the
HP
StorageWorks 1510i Modular Smart Array maintenance and service guide
.
Determining installed version
To determine the
rmware installed on an MSA1510i controller, do one of the following:
On the MSA controller LCD panel, press the ^ v keys to scroll through the messages until the
ARRAY
CONTROLLER FIRMWARE VER <version>
message is displayed.
In the MSA-CLI, use the
SHOW VERSION
command.
In the Storage Management Utility (SMU) , select
View MSA1510i Controller
.
HP StorageWorks 1510i Modular Smart Array
rmware 2.0 release notes
7