Power supply requirements for Director blades, Number of blades, Director blade
![]() |
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Director blade Number of blades FX8-24 (DC SAN Director Multi-protocol Extension Blade) FCOE10-24 (DC SAN Director Switch 10/24 FCoE Blade) Supported with Fabric OS 6.3.0x, with a maximum of two blades per director. The DC SAN Director Switch 10/24 FCoE Blade can be installed in the same chassis only with FC8-xx and/or FC10-6 blades. It is not supported in the chassis with any other blades. Power supply requirements for Director blades Table 4 lists power supply requirements for Director blades to provide full redundancy (220 VAC power is assumed). IMPORTANT: Director blades must meet the minimum Fabric OS levels to operate in the Director chassis. For example, the FC8-32 is not supported in the 4/256 SAN Director with Fabric OS 6.0.x. Table 4 Power supplies required for blades in Director chassis Director blade 4/256 SAN Director FC4-16 FC4-32 FC4-48 FC8-16 FC8-32 FC8-48 FC10-6 Two power supplies Four power supplies FR4-18i (FCIP/FC Router blade) Four power supplies FC4-16IP (iSCSI blade) DC SAN Backbone Director and DC04 SAN Director Two power supplies1 Two power supplies2 Two power supplies. The FC4-16IP blades are not supported in the DC SAN Backbone Director or DC04 SAN Director.2 18